Safety information
Operating instructions RLD 9
ELTROPLAN
-
REVCON
Elektrotechnische Anlagen GmbH
2
Safety information
Safety and application notes
for drive converters
(Low-Voltage Directive (2006/95/EEC)
1.
General
During operation, power feedback unit may have, according to
their type of protection, live, bare, in some cases also movable or
rotating parts as well as hot surfaces.
Non –authorized removal of required cover, inappropriate use, in-
correct installation or operation, creates the risk of severe injury to
persons or damage to material assets.
Further information can be obtained from the documentation.
All operations concerning transport, installation and commission-
ing as well as maintenance must be carried out by qualified,
skilled personnel (IEC 364 and CENELEC HD 384 or DIN VDE
0100 and IEC-Report 664 or DIN VDE 0110 and national regula-
tions for the preventions of accidents must be observed).
According to this basic safety information qualified skilled per-
sonnel are persons who are familiar with the erection, assembly,
commissioning and operation of the product and who have the
qualifications necessary for their occupation .
2.
Application as directed
Power feedback units are components which are designed for in-
stallation in electrical systems or machinery.
When installing in machines, commissioning of the power feed-
back unit (i.e. the starting of operation as directed) is prohibited
until it is proven, that the machine corresponds to the regulations
of the EC Directive (2006/42/EG) (Machinery Directive); EN
60204 must be observed.
Commissioning (i.e. starting operation as directed) is only allowed
when there is compliance with the EMC-Directive
(2004/108/EG).
The power feedback units meet the requirements of the Low-
Voltage Directive (2006/95/EEC). The harmonized standards of
the prEN 50178/DIN VDE 0160 series together with EN 60439-
1/DIN VDE 0660 part 500 and EN 60146/DIN VDE 0558 are ap-
plicable for the power feedback unit. The technical data and in-
formation on the connection conditions must be obtained from the
nameplate and the documentation and must be observed in all cas-
es.
3.
Transport, Storage
Notes on transport, storage and appropriate handling must be ob-
served.
At non-observance any warranty expires.
The power feedback unit has to be protected from inadmissible
stress.
The transport is only valid in original packaging and in the there-
on by pictograms marked transport position.
In particular during transport and handling no components are al-
lowed to be bent and / or isolating distances may not be altered.
The units are equipped with electrostatic sensitive devices, which
may be damaged by improper handling. Therefore it has to be
avoided to get in contact with electronic components. If electronic
components are damaged mechanically the unit must not be put
into operation, as it cannot be ensured, that all relevant standards
are observed. Climatic conditions must be observed according to
prEN 50178.
4.
Erection
The devices must be erected and cooled according to the regula-
tions of the corresponding documentation.
The power feedback units must be protected from inappropriate
loads. Particularly during transport and handling, components
must not be bent and / or isolating distances must not be
changed. Touching of electronic components and contacts must
be avoided.
Power feedback units contain electro-statically sensitive com-
ponents which can easily be damaged by inappropriate han-
dling. Electrical components must not be damaged or destroyed
mechanically (health risk are possible!).
5.
Electrical Connection
When working on live power feedback units, the valid national
regulations for the prevention of accidents (e.g. VBG 4) must be
observed. Before any installation or connection works, the plant
has to be switched off and to be secured properly.
The electrical installation must be carried out according to the ap-
propriate regulations (e.g. cable cross-sections, fuses, PE-
connection). More detailed information is included in the docu-
mentation. When using the power feedback unit with controllers
without safe separation from the supply line (to VDE 0100) all
control wiring has to be include in further protective measures
(e.g. double insulated or shielded, grounded and insulated) .
Notes concerning the installation in compliance with EMC – such
as screening, grounding, arrangement of filters and laying of ca-
bles – are included in the chapter installation of this documenta-
tion. These notes must be also observed in all cases for power
feedback units with the CE-mark. The compliance with the re-
quired limit values demanded by the EMC legislation is the re-
sponsibility of the manufacturer of the system or machine.
6.
Operation
Systems where power feedback units are installed, if applicable,
have to be equipped with additional monitoring and protective
devices according to the valid safety regulations e.g. law on
technical tools, regulations for the prevention of accidents, etc. .
After disconnecting the power feedback unit from the supply
voltage, live parts of the power feedback unit and power con-
nections must not be touched immediately, because of possibly
charged capacitors. For this, observe the corresponding labels
on the drive controllers.
During operation, all covers and doors must be closed.
7.
Maintenance and service
The manufacturer’s documentation must be observed.
This safety information must be kept
!
The product-specific safety and application notes in these Oper-
ating Instructions must also be observed!
Содержание REVCON RLD
Страница 46: ...Installation Operating instructions RLD 45 ELTROPLAN REVCON Elektrotechnische Anlagen GmbH 2 Enclosure 0 340 ...
Страница 47: ...Installation 46 Operating instructions RLD ELTROPLAN REVCON Elektrotechnische Anlagen GmbH 3 Enclosure 0 341 ...
Страница 48: ...Installation Operating instructions RLD 47 ELTROPLAN REVCON Elektrotechnische Anlagen GmbH 4 Enclosure 0 400 ...
Страница 49: ...Installation 48 Operating instructions RLD ELTROPLAN REVCON Elektrotechnische Anlagen GmbH 5 Enclosure 1 501 ...
Страница 50: ...Installation Operating instructions RLD 49 ELTROPLAN REVCON Elektrotechnische Anlagen GmbH 6 Enclosure 2 701 ...
Страница 51: ...Installation 50 Operating instructions RLD ELTROPLAN REVCON Elektrotechnische Anlagen GmbH 7 Enclosure 3 800 ...
Страница 52: ...Installation Operating instructions RLD 51 ELTROPLAN REVCON Elektrotechnische Anlagen GmbH 8 Enclosure 3 801 ...