Electrical Installation
70 Operating instructions RLD
ELTROPLAN
-
REVCON
Elektrotechnische Anlagen GmbH
4.4.2
Fan supply
All power feedback modules to enclosure 2/701 are provided with an internal fan supply.
The power feedback modules beginning with enclosure 2/701 require the in the ordering
code specified auxiliary voltage (230V or 115V).
4.4.3
Control wires
Connect the control wires to the terminal row X2 at the control plate of the power
feedback unit.
Don’t parallel control wires to interfering power wires.
Connect the screening of the control wires with an as big as possible surface to the
metal cable glands of the flange.
4.4.4
Control functions
The control terminal strip is placed on the control board and is indicated with X2. It is fit-
ted with a plug-in device for easy handling in case of service.
The control board must always be designed for the respective main circuit voltage. There-
fore the main circuit voltage (400V) must be declared with every order. This is also neces-
sary for a possible exchange of the device.
From the control terminal strip the operating condition or rather the collective error can be
connected to extern. There is also the possibility to execute the external reset or the switch-
functions and to connect them with the controller or the PLC.
4.4.4.1
Control terminals of Version A
Information of this chapter refer to units with type code ending on …-A
Содержание REVCON RLD
Страница 46: ...Installation Operating instructions RLD 45 ELTROPLAN REVCON Elektrotechnische Anlagen GmbH 2 Enclosure 0 340 ...
Страница 47: ...Installation 46 Operating instructions RLD ELTROPLAN REVCON Elektrotechnische Anlagen GmbH 3 Enclosure 0 341 ...
Страница 48: ...Installation Operating instructions RLD 47 ELTROPLAN REVCON Elektrotechnische Anlagen GmbH 4 Enclosure 0 400 ...
Страница 49: ...Installation 48 Operating instructions RLD ELTROPLAN REVCON Elektrotechnische Anlagen GmbH 5 Enclosure 1 501 ...
Страница 50: ...Installation Operating instructions RLD 49 ELTROPLAN REVCON Elektrotechnische Anlagen GmbH 6 Enclosure 2 701 ...
Страница 51: ...Installation 50 Operating instructions RLD ELTROPLAN REVCON Elektrotechnische Anlagen GmbH 7 Enclosure 3 800 ...
Страница 52: ...Installation Operating instructions RLD 51 ELTROPLAN REVCON Elektrotechnische Anlagen GmbH 8 Enclosure 3 801 ...