Technical data
30 Operating instructions RLD
ELTROPLAN
-
REVCON
Elektrotechnische Anlagen GmbH
Note!
To calculate the correct value of regenerating power it is necessary to note, that the real momen-
tary regenerating power is dependent on the real existing main circuit voltage at any time. To
calculate the regenerative power the following formula should be used:
P = U
eff
· I
eff
·
√
3
· cos
(during feedback operation cos
= 1 is valid)
The maximum possible regenerative power is calculated based on the momentary RMS mains
voltage and the maximum RMS current of the respective device. For example:
Device type RLD E0 48 with rated feedback power of 48kW, maximum rated RMS current 69A
(refer to technical data), nominal mesh voltage rating 400V.
From that results: P=400V x 69A x
√3
=47805W, that’s about 48,0kW
If the momentary RMS mains voltage is only 395V or even lower for a short time, the maximum
possible regenerative power is reduced as well:
P = 395V x·69A x
√3
= 47207W, that’s about 47,2kW.
REVCON RLD E0
Nominal voltage 400V
REVCON
®
- type
AC
Max. current I
rms
[A]
DC
Max. current I [A]
REVCON
Article- Number
RLD-E0 2-400-50-0-B
3
4
21016900
RLD-E0 4-400-50-0-B
6
7
21016901
RLD-E0 8-400-50-0-B
12
14
21016902
RLD-E0 12-400-50-0-B
17
20
21016903
RLD-E0 16-400-50-0-B
23
28
21016904
RLD-E0 20-400-50-0-B
29
35
21016905
RLD-E0 24-400-50-0-A
35
42
21016005
RLD-E0 32-400-50-0-A
46
55
21016006
RLD-E0 40-400-50-0-A
58
70
21016007
RLD-E0 48-400-50-0-A
69
83
21016008
RLD-E0 58-400-50-0-A
84
101
21016009
RLD-E0 80-400-50-0-A
116
139
21016010
RLD-E0 95-400-50-0-A
137
165
21016011
RLD-E0 116-400-50-0-A
168
202
21016012
RLD-E0 140-400-50-0-A
202
242
21016013
RLD-E0 170-400-50-0-A
246
295
21016014
RLD-E0 200-400-50-0-A
290
348
21016015
RLD-E0 230-400-50-0-A
332
398
21016016
RLD-E0 265-400-50-0-A
383
460
21016017
RLD-E0 300-400-50-0-A
434
521
21016018
RLD-E0 345-400-50-0-A
500
600
21016019
Table 3.3.1.2
Содержание REVCON RLD
Страница 46: ...Installation Operating instructions RLD 45 ELTROPLAN REVCON Elektrotechnische Anlagen GmbH 2 Enclosure 0 340 ...
Страница 47: ...Installation 46 Operating instructions RLD ELTROPLAN REVCON Elektrotechnische Anlagen GmbH 3 Enclosure 0 341 ...
Страница 48: ...Installation Operating instructions RLD 47 ELTROPLAN REVCON Elektrotechnische Anlagen GmbH 4 Enclosure 0 400 ...
Страница 49: ...Installation 48 Operating instructions RLD ELTROPLAN REVCON Elektrotechnische Anlagen GmbH 5 Enclosure 1 501 ...
Страница 50: ...Installation Operating instructions RLD 49 ELTROPLAN REVCON Elektrotechnische Anlagen GmbH 6 Enclosure 2 701 ...
Страница 51: ...Installation 50 Operating instructions RLD ELTROPLAN REVCON Elektrotechnische Anlagen GmbH 7 Enclosure 3 800 ...
Страница 52: ...Installation Operating instructions RLD 51 ELTROPLAN REVCON Elektrotechnische Anlagen GmbH 8 Enclosure 3 801 ...