56
English
c. Broken belt:
A drive belt can break at the end of its life. The drive towards the blade has two belts. If one
of the two belts breaks, the entire load is carried by a single belt, which is also nearing the
end of its life. In this case slippage may occur, causing irregular movements of the blade. In
this case it is recommended to replace both belts. Consult your authorised ELIET dealer for
more information.
d. Technical defect:
If neither of the aforementioned checks identifies the cause, the problem could be more
technical in nature. It may concern a defect in the transmission box, connecting rods, carri-
age, belt discs, etc. Visit your authorised ELIET dealer to have them carried out.
9.11.4. The machine will not drive or is driving irregularly.
If the machine feels jerky when driving or always veers off in one direction there will be a disrup-
tion to the drive. This could be caused by a number of reasons:
a. Broken cable:
The command to activate the drive is given by a lever which activates the primary belt drive
to the hydrostatic pump via a cable. This cable is subject to wear and can also break after
some time. If the cable breaks, the drive becomes uncoupled. This is immediately obvious
because there is no longer resistance on the operating lever. In this case, the cable must be
replaced. Consult your authorised ELIET dealer.
b. Belt tension:
The belt that drives the hydrostatic pump tends to stretch. This means that the tension on
this belt decreases over time. At a certain moment this can cause a belt to slip. When it slips,
the drive briefly stops causing the machine to splutter when driving. Also, when more pres-
sure is placed on the drive (e.g. driving up a slope) this belt can slip causing a loss of traction.
When the belt slips it can cause a peeping noise. This can be resolved by tightening the belt
tension: (read § 11.5.3; page 71)
c. Broken belt:
A single belt transfers the engine capacity to the hydrostatic pump. Every drive belt can
break at the end of its life. If the belt breaks, the drive to the hydrostatic pump stops, thus
stopping the machine. Consult the authorised ELIET dealer to replace this belt.
d. Oil leak
The drive to the tracks is hydraulic. This is a closed circuit. If there is a leak in this circuit
there will be a leak of oil. The drive cannot work if there is insufficient oil. A leak is visible
because traces of oil are found under the machine. Check the oil level in the hydraulic tank.
However, a leak can also cause air to enter the hydraulic circuit. Air in the pipes leads to irre-
gular operation of the hydraulic pomp and the hydraulic motors. Try to track down an oil leak
as quickly as possible. Consult the authorised ELIET dealer to resolve this problem.