RIGENERATIVE
SINUS PENTA
APPLICATION
78/
140
0
1
2
3
4
0
1
2
3
4
M512 Phase R Line Current (RMS)
M512
Range
±
32000
±
3200.0 A
Address
1662
Function
RMS of phase R line current.
M513 Phase S Line Current (RMS)
M513
Range
±
32000
±
3200.0 A
Address
1663
Function
RMS of phase S line current.
M514 Phase T Line Current (RMS)
M514
Range
±
32000
±
3200.0 A
Address
1664
Function
RMS of phase T line current.
M515 PLL Status for Synchronization with the Mains
M515
Range
0
÷
4
See
Table 2
Address
1665
Function
This parameter displays the status of the PLL (Phase Locked Loop) for the
synchronisation with the AC mains. The phase sequence is checked as
well.
N.
Display
Description
0 IDLE
PLL
stopped
1
INIT POS.
Positive phase sequence detected waiting for synchronization
2
INIT NEG.
Negative phase sequence detected waiting for synchronization
3
LOCK POS.
Positive phase sequence synchronized
4
LOCK NEG.
Negative phase sequence synchronized
Table 2: Codification of Measure M515.