C257 Alarm Reset at Power On
C257
Range
0 ÷ 1
0: [Disabled]; 1: [Yes]
Default
0
0: [Disabled]
Level
ENGINEERING
Address
1257
Function
At power on, this parameter enables the automatic reset of the alarms
tripped when the drive is powered off.
C258 Enable TLP Fault Autoreset
C258
Range
0 ÷ 1
0: [Disabled]; 1: [Yes]
Default
0
0: [Disabled]
Level
ENGINEERING
Address
1258
Function
This parameter enables the Autoreset function for the TLP fault; the autoreset
attempt number is set in C255.
C259 Enable CFilt Fault Autoreset
C259
Range
0 ÷ 1
0: [Disabled]; 1: [Yes]
Default
0
0: [Disabled]
Level
ENGINEERING
Address
1259
Function
This parameter enables the Autoreset function for the Cfilt fault; the autoreset
attempt number is set in C255.
C260 Enable Mains Fault Autoreset
C260
Range
0 ÷ 1
0: [Disabled]; 1: [Yes]
Default
0
0: [Disabled]
Level
ENGINEERING
Address
1260
Function
This parameter enables the Autoreset function for the mains fault; the
autoreset attempt number is set in C255.
C261 Enable Autoreset for External Alarm
C261
Range
0 ÷ 1
0: [Disabled]; 1: [Yes]
Default
0
0: [Disabled]
Level
ENGINEERING
Address
1261
Function
This parameter enables the Autoreset function for external alarms; the
autoreset attempt number is set in C255.