3.4.
ADE REGISTERS MENU
3.4.1.
O
VERVIEW
This submenu allows calibrating the measures contained in Menu n.2 – ADE Measures. ES847 option board
and its external components are required (please refer to the Sinus Penta’s Installation Instructions manual).
To activate ES847 board, set parameter R023=5:XMDO+ADE or 6:XMDO+ADE+Pout (see the EXPANSION
BOARD CONFIGURATION MENU).
NOTE
Measures can be set up
either
from ADE
or
from PT100 (see the SETTING
“ADE” is part of the name of the integrated circuit (ADE7758) installed in ES847 board. This integrated circuit
ensures high-precision three-phase measurement of electric energy, and is capable of detecting active energy,
reactive energy, apparent energy and of calculating RMS values.
This integrated circuit complies with the following standards: IEC 1036, IEC 61036 and following
amendments.
Particularly, standard IEC 61036:1996 covers “Alternating current static watt-hour meters for active energy
(classes 1 and 2)”.
ADE7758 provides calibration characteristics for each phase, such as offset/gain/phase/power correction.
ADE registers are described below.