37
control circuitries comprise microprocessors.) Modular-designed electronics facilitate mounting and
maintenance easily.
6.2 DETECTION FIELD
ThruScan
’s multi-zone detection field provides and completes horizontal and vertical uniformity.
The sensitivity of each field can be adjusted to meet the requirements of specific security
applications
(*only for
sX/ sX-WP /s15-i/sX-i
).
ThruScan
’s unique design enables the operator
to identify targets within 9 zones. Detection is precise, regardless of a target’s location or
orientation within the archway.
6.3 LANGUAGE
English & German & Turkish & Spanish is standard. (other languages optional)
6.4 SELF-TEST
As soon as your
ThruScan
is turned on, a self-test routine occurs for about 10 seconds during
which time the warning buzzer will sound to warn that the unit is not yet ready for use. Should a
fault in the system be detected a fault code will be displayed upon the LCD display.
Failure Codes
are as follows:
Error 00: The walk through infrared detector is blocked or failed.
Error 01: Left Top Zone - High Metal Detection for a prolonged period.
Error 03: Right Top Zone - High Metal Detection for a prolonged period.
Error 04: Left Centre Zone - High Metal Detection for a prolonged period.
Error 06: Right Centre Zone - High Metal Detection for a prolonged period.
Error 07: Left Bottom Zone - High Metal Detection for a prolonged period.
Error 09: Right Bottom Zone - High Metal Detection for a prolonged period.
Error 11: Left Top Zone - No Detection for a prolonged period.
Error 13: Right Top Zone - No Detection for a prolonged period.
Error 14: Left Centre Zone - No Detection for a prolonged period.
Error 16: Right Centre Zone - No Detection for a prolonged period.
Error 17: Left Bottom Zone - No Detection for a prolonged period.
Error 19: Right Bottom Zone - No Detection for a prolonged period.
(*for s3
only 6 error codes i.e.; 00, 06(right panel), 07(left panel), 16(right panel),
17(left panel), 26 is existing)
NOTE: 1)
ThruScan
also continually monitors itself during normal use. Should any of the
above conditions be detected the fault code will be displayed. If no cause is ascertained
pls. contact to the supplier, service company or factory.
2) WTMD,
ThruScan
may display a failure code(error 19) if not used or screened for a
long time. In such case try and screen your WTMd with an unclean object with metal. If
error message continue pls. contact your service company or supplier. Thus be sure
that detection is performed in all areas
.