26
The assigned sensitivity level in this MENU is approximate. For more
precise security requirements, it is recommended that the user
decides on the necessary sensitivity level by using the displayed (AD)
sensitivity level only as a reference and proceed further adjustments
manually.
4.1.4 ALARM VOLUME & TONE ADJUSTMENT
ThruScan
has 11 separate alarm volume levels, in 10 different tones from 1(quietest) to
10(loudest) as well as 00, which disables the audible alarm tone (but not the visual indication).
The Factory default alarm volume setting is = 05
The Factory default tone setting is = 09
The alarm volume can be set as follows:
1.
Press UP&DOWN buttons from the MENU until the ALARM
VOLUME sub-MENU option is displayed,
2.
Current Alarm Volume will be displayed, (i.e. 05 displayed),
3.
Use UP&DOWN buttons to reach the required volume setting,
4.
To fix the alarm volume press the SEL(√) button then
“TONE” will be automatically displayed,
5.
Use UP&DOWN buttons to reach the required tone type,
6.
Press SEL(√) button to select and fix the setting.
Press
UP&DOWN
buttons to move to the next
sub
-MENU option or
press
RUN(X)
button to store the changes and thus return to the
normal operating mode.
4.1.5 ALARM COUNTERS
4.1.5.1
FOR;
ThruScan
s3/s6/s9
ThruScan
has an internal alarm counter and memory where the number of alarms after a reset are
saved. This information can be displayed from “ALARM COUNTER”.
The alarm memory can be viewed or reset as follows:
1.
Press
UP&DOWN
buttons from the MENU until
ALARM
COUNTER sub-
MENU option is displayed.
2.
The LCD will display the number of the counted alarms stored in memory;
3.
To reset the counter press
SEL(√)
button to enter the reset
MENU,
4.
Use
UP&DOWN
buttons to select either
N
(do not reset) or
Y
(reset) the alarm counter,
5.
Press
SEL(√)
button to select and fix the setting.
SECURITY LEVEL
ECAC STD1
ECAC STD2
ECAC STD3
NIJ 0601.02 SMALL
MAIN MENU
FACTORY SETTINGS
LANGUAGE
COUNTER VISIBILITY
ALARM COUNTER
000125
ALARM COUNTER
000125
RESET Y<=>N
Y
ALARM VOL. AND TONE
[05], [09]
VOLUME LEVEL
05
TONE
09
AD