49
8. MAINTENANCE & REPAIR
8.1. PERIODIC MAINTENANCE
Periodic maintenance requires that you inspect for loose or damaged parts and clean the surface of
the
ThruScan
‘s
exterior. The following procedure is recommended;
1
. Open the rear cover of the Control Unit and ensure that all connectors are snapped and screwed
securely,
2
. Inspect the windows of the “IR Pass Sensors” to ensure they are not obstructed,
3
. Ensure that the eight bolts that attach the “Control Unit” and “Back Fixing Crosspiece” to the
side panels are in place and tight,
4
. Ensure that the archway sits flatly on the floor and does not sway or rock,
5
. Ensure that the power cord and cable to remote WTMDs are in good condition. If defected
replace immediately,
6
. Clean exterior surfaces with damp cloth. Use only denatured alcohol for heavy-duty cleaning.
Please remember that the plastic parts are made by ABS and the metallic parts are painted by
electrostatic epoxy paint.
For
ThruScan sX-WP,
additional maintenance is required in the event of extreme weather
conditions such as snow.
8.2. REPAIR
The modular design of
ThruScan
facilitates mounting, dismounting and maintenance. It is easy to
follow procedures with its user-friendly MENU. If problems are detected, see section 9.1. General
problems related with Mounting and Operating are explained here.
You may always get updated and detailed information from our web-site
If problems are related with the environment, see Section 2.1 or contact your Dealer or our
Company for assistance. Adjusting or relocating the or removing nearby objects or just checking
the mains ground if it is properly done often solves the problem of WTMD failures.
If the equipment does not perform properly please do not hesitate to contact your dealer or our
Company for any assistance.
8.3. MODULE REPLACEMENT
The system comprises a series of removable and replaceable modules that are tested and
calibrated independently thereby eliminating the need for adjustments to the electronic mounting.
However, after any component is replaced, the system must be tested thoroughly to confirm that
ThruScan
operates properly.
8.4. WARRANTY PROVISIONS
ELEKTRAL® A.S (“Elektral®”) warrants conditionally that this
ThruScan
Metal Detector is protected
by the following limited warranty (for components and labour) for a period of 24 months (pls. see
our “Warranty Conditions”). During this 24-month period ELEKTRAL® will inspect and evaluate all
security equipment returned to its authorised repair station or factory to determine if the
equipment meets Elektral®’s performance specifications. Elektral® will repair or replace—at no
charge to the owner—all parts determined faulty. Elektral® Elektromekanik Sanayi ve Ticaret
Anonim Sirketi always hold the authorization to determine whether the failure is in accordance with
her “Warranty Conditions” however our main motto is to satisfy and please our customers. All