17
2.2.2 Arrange the major components as shown above.
2.2.3 Lay the main Control Unit
(with the control panel facing down)
onto a soft, scratch free
surface
(the packing (bubbled pe) is ideal)
.
2.2.4 Remove the rear panel of the main Control Unit by undoing the two small fixing screws.
Retain these screws to screw them back in their places later
(Note: The arrow signs on the control unit and the panel parts, which are fixed on the
top of each other, have to point to the same direction)
.
2.2.5 Using the Eight Panel Fixing Bolts (4 on each side), screw two side panels to “Control Unit”
(
ThruScan
s3/s6/s9 two Screws on each panel) do not fully tighten at this stage.
2.2.6 Plug in the side panel connectors to the main Control Unit (take the numbers written on them
[sX-i] in consideration) as follows:
Left Side Panel – Connect the Side Panel Sockets in to the connector of the Control Unit
(ThruScan s3/s6/s9 models have two sockets)
Right Side Panel – Connect the Side Panel Socket to the Connector on the Control Unit
Note: This WTMD is designed to prevent false connector/socket connection.
2.2.7 Place back the rear panel of the main Control Unit using the three small fixing screws
previously removed
(see 2.2.4 above)
.
2.2.8 Attach the back fixing crosspiece using the remaining four panel fixing bolts (only
ThruScan
s3/s6/s9);
do not fully tighten at this stage
.
2.2.9 Remove four hex bolts holding the floor fixing plates at the bottom of each side panel using
the Allen key.
2.2.10 Use two or more people to lift your WTMD carefully to a vertical position and move to
desired location. Ensure the two side panels are perfectly aligned parallel to each other with 74cm
spacing between panels.
CAUTION! The WTMD will not operate fully functional if the side panels and the infrared
sensors are not aligned properly.
2.2.11 Carefully mark the Side Panel Erection Positions on the floor, and fix the floor fixing metal
plates onto the floor. Put the WTMD Side Panels into floor fixing plates making sure the plates will
fit inside the Side Panels, using Allen key
(see 2.2.9 above)
tighten the plates only to prevent from
moving; DO NOT over tighten. Stabilisation for ThruScan Sx-i model can be done using the holes at
the tip of each foot.
2.2.12 Ensure that
ThruScan
is physically stable.
2.2.13 Fully tighten all bolts with the installation spanner.
2.2.14 Finally, ensure that the Mains Power Cord is connected to the Connector at the back of the
Control Unit.