Frequently Asked Questions VESDA Sensepoint
XCL – Micro / Large
Bore Gas Detectors
www.acornfiresecurity.com
Страница 1: ...Frequently Asked Questions VESDA Sensepoint XCL Micro Large Bore Gas Detectors www acornfiresecurity com www acornfiresecurity com ...
Страница 2: ...sked Questions VESDA Sensepoint XCL Micro Large Bore Gas Detectors Doc 35229_03 Table of Contents 1 VESDA Sensepoint XCL Micro Large Bore ASD Gas Detectors FAQs 2 www acornfiresecurity com www acornfiresecurity com ...
Страница 3: ...SDA Sensepoint XCL Micro Large Bore detect A Gases Micro Bore Large Bore Carbon Monoxide CO ppm Flammable gases CH4 H2 etc LEL Carbon Dioxide CO2 v v ppm Hydrogen H2 ppm Oxygen O2 v v Hydrogen Sulphide H2S ppm Nitrogen Dioxide NO2 ppm Ammonia NH3 ppm Q What outputs versions are supported by VESDA Sensepoint XCL Micro Large Bore A Relay output 2x Relays 5A 250vAC 24VDC o Fault o Alarm Analog output...
Страница 4: ...ge Bore can connect at any point of the pipe network Use ASPIRE pipe modelling tool to validate pipe network performance transport time hole pressure flow under such conditions Q How many VESDA Sensepoint XCL Micro Bore detectors can connect to a single VEA tube A x2 VESDA Sensepoint XCL Micro Bore detectors per tube total of 80 per VEA unit Q How many VESDA Sensepoint XCL Large Bore detectors can...
Страница 5: ...re can I find the Sensepoint App A The Sensepoint App can be obtained free of charge from Google Play Store and Apple App Store Q What is the smart device requirement for installing Sensepoint App A Android 4 3 Jelly Bean iOS 10 or above Bluetooth 4 0 wireless interface Q What is the max distance covered by Wireless interface A 10m 33ft smart device dependent Q What value do VESDA Sensepoint XCL g...
Страница 6: ...e VESDA Sensepoint XCL Large Bore support A This will vary depending on Target gas concentration Number of sample holes upstream the VESDA Sensepoint XCL detector Dilution of gas in the pipe VESDA Sensepoint XCL lower alarm level LAL Refer to the VESDA Sensepoint XCL Large Bore Alarm Setting Calculator Sheet Doc No 35758 for setting detector alarm levels for given target gas concentration and supp...
Страница 7: ...ood beverage industry Underground areas tunnels chambers Pharmaceuticals Chemical Laboratories Confined spaces Water treatment plants Laboratories Hospitals Ammonia ppm Agriculture Petroleum Chemical industries Hospitals Refrigerated plants Pulp and Paper industry Food beverage industry Q Who do I contact for VESDA Sensepoint XCL enquiries A If you have any questions on VESDA Sensepoint XCL Large ...