40
6.14 ELECTRICAL REQUIREMENTS
Operating voltage:
70 – 270 VAC (supply should be well grounded/earthed and the ground must
be in proper electrical norms) - 50/60 Hz.
*External SMPS (Input:100-240 vac, 50/60Hz, 1.0 A Output: 15 vdc, 2.66 A)
(*only
ThruScan
sX WP)
Power consumption: 10 Watts in standby mode
20 Watts in alarm mode (max)
6.15 CONSUMPTION EFFICIENCY
As described in article nr. 6.14 above, electrical values can be found. WTMDs are being produced to
operate 7/24.
However, for energy saving the WTMD is recommended to be in Stand By mode when there are no
passers by.
6.16 OPERATING TEMPERATURES
(-4º F) -20º C to +(158º F) +70º C
6.17 HUMIDITY
Up to 95% non-condensing.
6.18 THROUGHPUT/TRAFFIC RATE
High speed detection circuitry enable a high transition of approximately 50~60 persons per minute
(may vary with the metal magnitude) depending on the alarm activation delay.
(* for s3/s6 30~40 persons/min)
6.19 WEIGHT (~ kgs.)
ThruScan
s3/s6/s9
ThruScan
sX/s15-i/sX-i
Main control & display unit : 7.9
Main control & display unit : 7.9
Back fixing crosspiece
: 2.8
Back fixing crosspiece
: 2.8
Each side panel
: 16
Each side panel
: 19
Fixing apparatus
: 3.6
Fixing apparatus
: 3.6
Assembled weight
: 45.6
Assembled weight
: 52.3
Packaged weight
: 65
Packaged weights
: 70
ThruScan
sX-WP:
75 Kgs ( 3 Boxes)
6.20 WARRANTY PERIOD
24 months. (See Section 10.3) By the ministry a 10 years life span has been allocated.
6.21 DIMENSIONS*
ThruScan
s3/s6
ThruScan
s9/sX/sX-WP/s15-i
Interior(mm.) Exterior(mm.)
Interior(mm.) Exterior(mm.)
Width
740
850
740
850
Height
2000
2200
2000
2200
Depth
520
520
580
580
ThruScan
sX-i
Interior(mm.) Exterior(mm.)
Width
740
900
Height
2000
2200
Depth
580
580