16
2 INSTALLATION
2.1 TRANSPORTATION AND SITE SELECTION
ThruScan WTMDs are being packed and shipped in two separate boxes “Control Unit” and “Side Panels”.
Control Unit, Back Fixing Crosspiece and screws with Allen Keys are packed in the Control Unit Box
(*Only for ThruScan/s3/s6/s9). Side Panels and Floor Fixing Metal Plates are being packed in the Side
Panels Box. During transportation the Position Signs indicating upside on the Boxes have to be taken
into account for the equipment to be delivered correctly. Improper transportation may result in physical
damages on your equipment. When there is a need to relocate the WTMD, the WTMD has to be
unassembled, packed and delivered as described above before assembling again.
Before choosing a site for
ThruScan
, it is important to consider the volume and throughput of
pedestrian traffic, space availability and overall environmental conditions.
Position and fix
ThruScan
on a flat, stable floor where it remains unaffected by the sun, rain, mist or
condensation. If the WTMD will be used for a short time in outdoor then use “Rain Protect Shelter (Hat)”
as well as outdoor package.
(See Section 7.2).
ThruScan
sX-WP is produced for outdoor fulfilling IP55
standards.
To avoid external metal interference, ensure that there are no large metal items near
ThruScan
.
False alarms may be caused by nearby moving metallic objects such as an escalator or a revolving door
as well as due to an electrical interference from radio, telephones, television monitors, powerful
electronic motors and transformers.
Electrical installation of the WTMD should be from the ceiling.
Protect your WTMD from humidity and water since it is versatile electronic equipment or use our
Weather proof Model.
2.2
ASSEMBLING & MOUNTING
ThruScan WTMDs are designed for easy installation by the end users. Assembly can be done easily by
proceeding the below mentioned procedures. Also the Manufacturers contact details are provided in this
User’s Manual for further communication needs.
2.2.1 Verify that the following contents are included:
Left side panel
Right side panel
Main control & display unit
Back fixing crosspiece*
Mains power cord
Synchronization connection cable**
Rain Shelter***
4 floor fixing screws
8 panel fixing bolts
8 plastic bolt covers
Installation spanner (for panel fixing bolts)
Allen key (for floor fixing plates)
User’s manual
(*only for ThruScan s3/s6/s9)
(**optional)
(***only for ThruScan sX/WP)
Main Control & Display
Unit
Right
Side
Panel
Back fixing
crosspiece
Left
Side
Panel