57
1.6-
In “
Level Select
” window; 20 security levels are existing of which NC (NILECJ) can not be changed. The other 19
can be assigned to the desired sensitivity. Last channel AD (AUTO DESIGNATE) is assigned for the automatic
designation of the metal volume. (Pls. refer to your “Manual” for further information)
You can change several Security Levels simultaneously and send together to your Magnetic Walk-Thru Metal
Detector. Please note that; The sensitivity assignments performed at “Sensitivity Select” are for ALL ZONES !
To change the Security Level Adjustments:
d)
Press “
STOP
” button,
e)
Select the Security Level you want to change its sensitivity,
f)
Set it at a value between 0-245 ( 0- the most sensitive , 245- the less sensitive)
g)
“
Send
” it or them to your
ThruScan
. (One or more can be send at the same time ! )
1.7- By “
Zone Select
” section window; all zones can be adjusted separately.
1.8-
“
?
” signs for all windows are for “HELP” menu to ease you to use SRC-Scada Remote Control Program.
1.9- “
SEND
” button resets old data and memorize the new assigned data to your
ThruScan
.
1.10- “
Refresh
” button reports the data of your
ThruScan
in every 30 secs to your PC. You could get data instantly
every second by pressing “
Refresh
” button. “Send” is not possible in Refresh Mode.
1.11- “
Factory Settings
” button enables to return to default settings. These settings can be re memorized by “
SEND
”
button. Counter values do not change at this process.
1.12-
Select “Real Time” from the “Options” at the bottom of the SCADA screen in order to observe the detection,
counting, audible, visible alerts instantly.
Select from “Options”(1 to 5) to set the alarms duration on the screen.
1.13-
Select “Data Registration” from “Options” to register the history of incoming/outgoing and alarmed counter
values at an automatically opened file.
1.14-
“
X
” button is to exit from your SRC-SCADA Remote Control Programmer. This will shut down the
communication/telephone line also.
The author reserve the rights and disclaims all warranties as to this software, whether express or implied, including without limitation any implied warranties of
merchantability or fitness for a particular purpose. Use under your own responsibility, but comments (even critique) in English, German (or in Turkish) are welcome.
10.3 IRDA REMOTE CONTROL UNIT MANUEL
Pin Code Insertion:
It is necessary to insert 4 digit pin-code (****) to start procedures. Thus first 4 digit pin-code
numbers should be entered from remote.
(RUN(X)) button returns the WTMD to its operational model and exits from IRDA programming
mode.
:
a) Used to return back to operational mode(WTMD) after adjustments performed such as Security Level,
Alarm Tone Level. b) To return to sub-Menu from Remote Control Menu.
:
To shut off the alarm tone.
V +
:
To adjust the volume of alarm tone level. (increase/decrease)
CH
+
:
Security Level Adjustments. (increase/decrease)
:
Counter Visibility (on / off)
:
Alarm Counter Reset (make nil)
:
To Reset incoming/outgoing counters. (select 1 for incoming & select 2 for outgoing or select 3 for both
counters)
:
Return to factory defaults.