12 Home Automation Programming
iConnect Installation Manual
72
12.2.8.
Pulse Time
The Pulse Time determines the manner in which an HA unit responds to the On command. You can program each HA
unit switch on momentarily. This means that, on receiving the On command, the unit will be switched on for a
programmed amount of time. For example, you can program the hall light to switch on for 1 minute and automatically
switch itself off. Alternatively, the HA unit can be programmed to toggle on and off.
To program the Pulse Time for an HA unit:
1.
From the Programming menu, select HA Programming, HA Units [961].
2.
Select an HA unit (01-16).
3.
From the HA unit’s sub-menu, select Pulse Time [#10].
4.
Select 5 sec, 30 sec, 1 min, 2 min or Toggle.
12.2.9.
Descriptor
You can assign a 16-character descriptor for each HA unit. These descriptors help the user to identify the various HA
units installed around the home.
To edit an HA unit descriptor:
1.
From the Programming menu, select HA Programming, HA Units [961].
2.
Select an HA unit (01-16).
3.
From the HA unit’s sub-menu, select Descriptor [#11].
4.
Edit the descriptor using the alphanumeric keypad.
12.3.
House Code
The House code is part of the identification code of each HA unit. For the Home Automation features to function
correctly, the House code on each HA unit must be identical to the House code programmed in the system’s memory.
To program the system House code:
1.
From the Programming menu, select HA Programming, House Code [962].
2.
Using the arrow keys, select a House code from the options available (A-P).
12.4.
HA Control
The HA Control option allows you to enable or disable all Home Automation features for the entire system.
To program the Home Automation setting:
1.
From the Programming menu, select System Options, HA Control [963].
2.
Select Enabled or Disabled.
PGM output is not affected by HA Control parameter. Remote activation of PGM is possible,
even when HA control is disabled, as long as the PGM output trigger is defined as
Telecontrol – see p. 49
9.7.1 Output Trigger.
Содержание iconnect
Страница 79: ...Appendix A Menu Structure iConnect Installation Manual 75 ...
Страница 80: ...Appendix A Menu Structure iConnect Installation Manual 76 ...
Страница 81: ...Appendix A Menu Structure iConnect Installation Manual 77 ...
Страница 82: ...Appendix A Menu Structure iConnect Installation Manual 78 ...
Страница 83: ...Appendix A Menu Structure iConnect Installation Manual 79 ...
Страница 84: ...Appendix A Menu Structure iConnect Installation Manual 80 ...