Appendix B: Transmitter Installation
iConnect
Installation Manual
87
Figure B- 12: Lens Coverage Diagrams EL-4745
Figure B- 13: Lens Coverage Diagrams EL-4745PI
EL-4745 complies with EN-50131 2-2 Grade 2 Class II Power Supply Type C
Dual Magnetic Contact/Universal Transmitter (EL-4601DZ)
The EL-4601DZ is a 2-Way wireless device that can be defined either as a magnetic contact, a universal transmitter or both
in combination. The EL4601DZ is for use with the iConnect Control System. When batteries need replacing, the EL-
4601DZ sends a low battery indication to the Control System.
1. Magnet
2. Antenna
3. Battery
Holder
4. LED
Indicator
5. Reed
switch
6. Tamper
Switch
7. Location of Wiring Knockout
8. PCB Release Tab
9. Terminal
Block
Figure B- 14: EL-4601DZ (Cover Off)
Registration Procedure
The EL-4601DZ must identify itself to the iConnect Control System as follows:
1.
Set the system to registration mode.
•
Go to the main menu and select [9]>[1]>[1] (Programming > Devices > Zones)
•
Select a zone and press '
√ʹ.
2.
Open the detector housing by inserting a small screwdriver at the bottom of the unit between the front and back
cover and twist the screwdriver to release the cover.
3.
Remove the divider separating the battery from the contacts on the battery holder. The detector will send a
transmission. If the transmission is successfully received by the system it will play a confirmation sound. If no
confirmation sound is heard send another transmission by pressing and releasing the tamper switch of the
device.
Содержание iconnect
Страница 79: ...Appendix A Menu Structure iConnect Installation Manual 75 ...
Страница 80: ...Appendix A Menu Structure iConnect Installation Manual 76 ...
Страница 81: ...Appendix A Menu Structure iConnect Installation Manual 77 ...
Страница 82: ...Appendix A Menu Structure iConnect Installation Manual 78 ...
Страница 83: ...Appendix A Menu Structure iConnect Installation Manual 79 ...
Страница 84: ...Appendix A Menu Structure iConnect Installation Manual 80 ...