Appendix B: Transmitter Installation
iConnect
Installation Manual
103
Selecting a Location
The 2-Way Wireless Gas Leak Detector will function effectively if installed in the correct location. Consider the following
before mounting the gas alarm:
•
Methane (Natural) Gas: Methane is lighter than air, therefore the greatest concentration of gas is found right
below the ceiling, and therefore the Wireless Gas Leak Detector should be installed on the wall,
approximately 30 cm (12”) below the ceiling.
•
Butane Gas: Propane and Butane are heavier than air, therefore the greatest concentration of gas is found
right above the floor level. The Wireless Gas Leak Detector should therefore be installed about 30cm (12”)
above the floor. Do not mount in a location where the gas alarm could be damaged by dirt, liquids, etc.
Do not install the detector on the ceiling or on the floor.
Figure B- 40: Gas leak detector installation location
•
Install the detector in close proximity to every gas-operated appliance.
Do not:
•
Install the gas detector directly on any gas appliance.
•
Install the gas detector in sealed or closed compartments or in an area where a wall or a closed door can
obstructs the flow of gas to the gas alarm.
•
Install the gas detector in locations where fans, open doors, open windows etc. may prevent gas from
reaching the detector.
•
Install the gas detector in any room where aerosols or ammonia are used (e.g. bathrooms).
Installation Procedure
1.
Remove the mounting bracket from your unit according to the illustrations below.
2.
1
2
3
Figure B- 41: Gas leak detector installation procedure (#1)
Figure B- 42: Gas leak detector installation procedure
(#2)
3.
Hold the Mounting bracket against the wall as a template and mark the locations for the 2 mounting holes.
4.
Using a 3/16-inch (5 mm) drill bit, drill two holes at the marks and insert wall plugs.
5.
Secure the mounting bracket to the wall.
6.
Line up the side slot of the bracket and the detector. Push the detector onto the mounting bracket and fix it. Pull the
detector outwards to make sure that it is securely attached to the mounting bracket.
7.
Connect the detector power cable to the wall power outlet.
Содержание iconnect
Страница 79: ...Appendix A Menu Structure iConnect Installation Manual 75 ...
Страница 80: ...Appendix A Menu Structure iConnect Installation Manual 76 ...
Страница 81: ...Appendix A Menu Structure iConnect Installation Manual 77 ...
Страница 82: ...Appendix A Menu Structure iConnect Installation Manual 78 ...
Страница 83: ...Appendix A Menu Structure iConnect Installation Manual 79 ...
Страница 84: ...Appendix A Menu Structure iConnect Installation Manual 80 ...