9 System Options
iConnect
Installation Manual
49
To program the Supervision Loss Indication setting:
1.
From the Programming menu, select System Options, Display, SV Loss Ind. [94064].
2.
Select Enabled or Disabled.
9.7.
PGM Output Options
PGM (1-2) and are programmable outputs that are triggered according to specific system status conditions, or by
remote command sent via PSTN, GSM, keyfob, keypad, or RP.
9.7.1.
Output Trigger
The Output Trigger option determines the conditions that activate and deactivate the PGM output.
To program the Output Trigger:
1.
From the Programming menu, select System Options, PGM Options [9407].
2.
Select a PGM Output.
3.
Select Output Trigger [#1].
4.
Select an Output Trigger option from the following table.
Table
9-1: PGM Output Trigger Options
Trigger Option
Activated by…
Deactivated by…
PGM Not Used
The PGM output is disabled
Full Arm
System "Full" armed
System disarmed or PGM Cut-off
Perimeter Arm
System "Perimeter" armed
Part Arm
System "Part" armed
Arm Status
Any arming method
Power Trouble
AC Loss or Low Battery conditions
AC restore or Battery restore
Tel. Line
Trouble
Telephone line supervision trouble
Telephone line restore
System Trouble
System trouble condition
System trouble restore
Medical
Medical alarm
Any arming method, system disarmed or
PGM Cut-off
Burglary
Burglary alarm
Fire Alarm
Fire alarm
Zone Status
*
Open zones (steady)
Bypassed zones (pulsing)
All zones closed and no zones bypassed
Entry/Exit
Entry/Exit delay follower
Siren
Built-in siren follower
WL Siren
Wireless siren follower
Telecontrol
Remote PGM activation (PSTN/GSM/keyfob/keypad/RP,
or via Internet in ELAS versions
321 and above
)
For certain trigger options, deactivation may be determined by the PGM Cut-off -- see p. 50,
9.7.4 PGM Cut-off. If the PGM Cut-off is programmed as 000 (continuous activation), the
PGM output shall remain activated until it is toggled by the relevant change in system
status.
9.7.2.
Output Type
The Output Type option determines whether the PGM output produces a steady or pulsed output.
To program the Output Type:
1.
From the Programming menu, select System Options, PGM Options [9407].
2.
Select a PGM Output.
3.
Select Output Type [#2].
4.
Select Steady or Pulsed.
The Zone Status, Siren and WL Siren trigger options have a fixed Output Type; there is no
need to program an Output Type for these options.
*
Zone Status functions only when the system is disarmed.
Содержание iconnect
Страница 79: ...Appendix A Menu Structure iConnect Installation Manual 75 ...
Страница 80: ...Appendix A Menu Structure iConnect Installation Manual 76 ...
Страница 81: ...Appendix A Menu Structure iConnect Installation Manual 77 ...
Страница 82: ...Appendix A Menu Structure iConnect Installation Manual 78 ...
Страница 83: ...Appendix A Menu Structure iConnect Installation Manual 79 ...
Страница 84: ...Appendix A Menu Structure iConnect Installation Manual 80 ...