To setup the firmware update mode:
1.
From the Programming menu, select Communications, Comm. Options, Rem. SW Update [95416].
2.
Select the Remote Firmware Update mode from the following table:
Table
10-2: Remote FW Update
Access option
Description
Always Enable
Update is always possible.
Disable
Firmware update is not allowed.
User Initiated
The user must perform SW Update from the Service menu in
order to establish a connection – see p. 28,
4.7.14
Remote
Firmware Update
.
10.8.5.
PSTN Country
In order to meet the requirements of local telecommunications authorities, default telephone line parameters have been
chosen for a number of different countries.
To program the PSTN Country:
1.
From the Programming menu, select Communications, Comm. Options, PSTN Country [95417].
2.
Select your country from the options available.
Electronics Line 3000 offers custom telephone line parameter settings for countries that do not appear in
the list of pre-defined options. If your country does not appear among the available options, select the
option Custom Settings.
10.8.6.
Dial Tone Wait
This option determines whether the system dials only when the dial tone is present or if the dialing is initiated
regardless of the dial tone.
To program the Dial Tone Wait option:
1.
From the Programming menu, select Communications, Comm. Options, Dial Tone Wait [95418].
2.
Select Enabled or Disabled.
10.9.
Event Options for Central Station Reporting
System events are divided into a number of different event groups. This division allows you to enable or disable
reporting or Two-Way Audio for a specific group of events.
The different event groups are as follows:
•
Burglary [#1]
•
Fire [#2]
•
Open/Close (arm/disarm) [#3]
•
Service [#4]
•
Power [#5]
•
Peripherals [#6]
•
RF Jamming [#7]
•
Medical
10.9.1.
Event Reporting
You can enable or disable event reporting per Event Group. This allows you to filter the type of events that are reported
to the central station.
To enable or disable reporting for an event group:
1.
From the Programming menu, select Communications, Event Options [955].
2.
Select an Event Group.
3.
From the event group’s sub-menu, select Report [#1].
4.
Select Enabled or Disabled.
Содержание iconnect
Страница 79: ...Appendix A Menu Structure iConnect Installation Manual 75 ...
Страница 80: ...Appendix A Menu Structure iConnect Installation Manual 76 ...
Страница 81: ...Appendix A Menu Structure iConnect Installation Manual 77 ...
Страница 82: ...Appendix A Menu Structure iConnect Installation Manual 78 ...
Страница 83: ...Appendix A Menu Structure iConnect Installation Manual 79 ...
Страница 84: ...Appendix A Menu Structure iConnect Installation Manual 80 ...