7 Devices
iConnect
Installation Manual
39
This parameter is relevant only to Burglary zones used as Normal, Entry/Exit, Follower, or
24 hours type.
To program the CMS Reporting option:
1.
From the Programming menu, select Devices, Zones [911].
2.
Select the zone you want to program.
3.
From the zone’s sub-menu, select CMS Rep. [#09]; the zone’s current CMS Rep. setting is displayed.
4.
Select either Enabled or Disabled.
7.3.9.
Repeater
The repeater is an additional module that extends the range of the wireless transmitters. For a detector to use the
repeater to relay transmissions to the system, you must define the Repeater option for its zone.
To program the Repeater option:
1.
From the Programming menu, select Devices, Zones [911].
2.
Select the zone you want to program.
3.
From the zone’s sub-menu, select Repeater [#10]; the zone’s current Repeater setting is displayed.
4.
Select either No Repeater or Use Repeater.
Do not register the same transmitter to more than one repeater or mis-operation will
occur.
7.3.10.
Sensor Parameters
For a number of 2-Way detectors (e.g. Video Verification PIR Detector EL-4755 and 4755PI) you can define specific
parameters through the control system. These parameters can be set in order to define how the device acts according to
the zone in which it has been installed
To program the sensor parameter option:
1.
From the Programming menu, select Devices, Zones [911].
2.
Select the zone you want to program.
3.
From the zone’s sub-menu, select Sensor Par. [#11]; the zone’s current Sensor Parameter setting is displayed.
4.
Define the parameters according to the relevant device.
5.
Press Χ, to exit the sensor parameters menu.
7.3.11.
Loop Type (Wired zone 33-34 only)
This option enables you to determine the zone’s loop type.
To program the Loop Type option:
1.
From the Programming menu, select Devices, Zones [911].
2.
Select the zone you want to program.
3.
From the zone’s sub-menu, select Loop [#01]; the zone’s current Loop type setting is displayed.
4.
Select either N.O., N.C. or E.O.L.R.
7.3.12.
Loop Response (hardwire zones 33-34 only)
The loop response determines how long a zone needs to be opened for the control system to generate an alarm. The
following loop response options are available:
•
Slow Loop (150ms) – used typically for PIR detectors, magnetic contacts, etc.
•
Fast Loop (50ms) – designed for use with shock detectors
To set loop response:
1.
From the Programming menu, select Devices, Zones [911].
2.
Select the zone you want to program.
3.
From the zone’s sub-menu, select Loop Resp. [#10]; the zone’s current Loop response is displayed.
4.
Select Slow Loop or Fast Loop.
Содержание iconnect
Страница 79: ...Appendix A Menu Structure iConnect Installation Manual 75 ...
Страница 80: ...Appendix A Menu Structure iConnect Installation Manual 76 ...
Страница 81: ...Appendix A Menu Structure iConnect Installation Manual 77 ...
Страница 82: ...Appendix A Menu Structure iConnect Installation Manual 78 ...
Страница 83: ...Appendix A Menu Structure iConnect Installation Manual 79 ...
Страница 84: ...Appendix A Menu Structure iConnect Installation Manual 80 ...