3 Basic System Operation
iConnect Installation Manual
18
The exit delays of the two arming modes are entirely independent. The moment an arming mode is activated, its exit
delay begins to count down. The entry delay depends on which detector was tripped first. For example, if the detector
is included in Full arming, the entry delay for Full arming counts down – see p. 37,
7.3.2 Arm Set. If the detector is
included in both activated arming modes, the entry delay for Perimeter arming counts down.
If, due to open zones, the system is not ready to activate the second arming mode then both
arming methods are canceled. In this case, check that the relevant entrances are secured and
start the entire arming sequence again.
Disarming cancels both active arming modes.
3.6.7.
Disarming
When an entry/exit detector is tripped, the entry delay counts down; each arming method has its own entry delay.
To disarm the system:
Enter a valid user code, the system is disarmed.
You can only disarm all the active arming modes.
3.7.
Additional Arming Options
3.7.1.
Forced Arming
Forced arming enables you to arm the system when the system is not ready. For example, if a door protected by a
magnetic contact is open, you may arm the system on condition that the door will be closed by the end of the Exit delay.
If the door is still open after the exit delay expires, an alarm is generated.
Two conditions enable you to perform Forced arming:
•
Forced arming is enabled – see p. 46,
9.3.1 Forced Arm.
•
The detector that is causing the System Not Ready condition is Force Arm enabled – see p. 38,
7.3.6 Force
Arm.
3.7.2.
Instant Arming
Instant arming is a feature that allows you to cancel the entry delay after Part or Perimeter arming the system. For this
feature to function, it must be enabled in programming – see p. 47,
9.3.4 Instant Arming.
To instantly arm the system.
1.
Check if the system is ready to arm.
2.
Press the Part or Perimeter arming key on the keypad and enter your user code if One-Key Arming is disabled.
3.
Press and hold down
on your keypad until the message Instant Arming, OK? is displayed
4.
Press '
√ʹ; the entry delay for the current arming period is canceled.
3.7.3.
Disarming
When an entry/exit detector is tripped, the entry delay counts down; each arming method has its own entry delay.
To disarm the system:
Enter a valid user code, the system is disarmed.
3.7.4.
Remote Arming/Disarming via SMS
You can arm and disarm the system remotely by sending the SMS commands from a cellular phone to the Cellular
Communication Module (GPRS or Ethernet). Additionally, you can check the arm status of the system by sending an
Arm Status request message.
Each SMS command contains the following elements:
SMS Command Descriptor (up to 43 characters of free text)
# (delimiter – separates the descriptor from the actual command)
User Code (4 digits)
Command (120=Disarm, 121=Full Arm, 122=Part Arm, 123=Perimeter Arm, 124=Full + Perimeter Arm, 125=Part
+ Perimeter Arm, 200=Arm Status)
The following example shows the format of an SMS command for arming the system:
Содержание iconnect
Страница 79: ...Appendix A Menu Structure iConnect Installation Manual 75 ...
Страница 80: ...Appendix A Menu Structure iConnect Installation Manual 76 ...
Страница 81: ...Appendix A Menu Structure iConnect Installation Manual 77 ...
Страница 82: ...Appendix A Menu Structure iConnect Installation Manual 78 ...
Страница 83: ...Appendix A Menu Structure iConnect Installation Manual 79 ...
Страница 84: ...Appendix A Menu Structure iConnect Installation Manual 80 ...