Appendix B: Transmitter Installation
iConnect Installation Manual
92
Table B- 2: LED Sensitivity Level (EL-4607)
LED
Sensitivity Level
Red
Under-sensitive indication
Green
Normal sensitivity (recommended)
Orange
Over-sensitive indication
2.
If required, adjust the Sensitivity parameter.
3.
Repeat the sensitivity test until you achieve the required sensitivity level.
4.
After you have adjusted the Sensitivity parameter, repeat the test once more.
5.
Close the front cover of the detector.
Deleting a Vibration Detector
To delete a vibration detector from the system:
1.
Set the system to Delete mode.
•
Go to the main menu and select [9]>[1]>[1] (Programming > Devices > Zones).
•
Select a zone and press '
√ʹ
2.
Press >12 >√.
3.
Open the detector and take out the battery.
4.
Press the tamper switch. While the tamper switch is being pressed insert the battery.
5.
Within five seconds open the tamper and close it again.
Smoke Detector (EL-4703)
The EL-4703 is a single station, photoelectric smoke detector with a built-in supervised wireless transmitter.
When sufficient smoke is detected, or the test feature is operated, the detector will sound its alarm horn and the
transmitter will send an ALARM message. The Alarm output in the receiver will remain activated until the alarm
condition clears.
The smoke alarm base lock discourages unauthorized removal of the smoke alarm by requiring a screwdriver to remove
the alarm from the base.
The smoke alarm provides the following signals to the control panel:
•
Alarm
•
Alarm restore
•
Low battery
•
Tamper
•
Supervision
WARNINGS:
This smoke detector is designed for use in a single residential unit only, which means that it
should be used inside a single family home or apartment. It is not meant to be used in
lobbies, hallways, basements, or another apartment in multi-family buildings, unless there
are already working detectors in each family unit. Smoke detectors, placed in common areas
outside of the individual living unit, such as on porches or in hallways, may not provide
early warning to residents. In multi-family buildings, each family living unit should set up
its own detectors.
This detector is not to be used in non-residential buildings. Warehouses, industrial or
commercial buildings, and special purpose non-residential buildings require special fire
detection and alarm systems. This detector alone is not a suitable substitute for complete fire
detection systems for places where many people live or work, such as hotels or motels. The
same is true of dormitories, hospitals; nursing homes or group homes of any kind, even if
they were once single - family homes. Please refer NFPA 101, the Life Safety Code, NFPA71,
72A, 72B, 72C, 72D, and 72E for smoke detector requirements for fire protection in buildings
not defined as “households”.
Содержание iconnect
Страница 79: ...Appendix A Menu Structure iConnect Installation Manual 75 ...
Страница 80: ...Appendix A Menu Structure iConnect Installation Manual 76 ...
Страница 81: ...Appendix A Menu Structure iConnect Installation Manual 77 ...
Страница 82: ...Appendix A Menu Structure iConnect Installation Manual 78 ...
Страница 83: ...Appendix A Menu Structure iConnect Installation Manual 79 ...
Страница 84: ...Appendix A Menu Structure iConnect Installation Manual 80 ...