9 System Options
iConnect Installation Manual
54
9.18.
Battery Type
The battery type must be defined according to the battery supplied with the system (for example, if the battery sticker
reads 1500 mAh, choose 1.5 Ah, if 3000 mAh, choose 3.0 Ah).
To program the battery type:
1.
From the Programming menu, select System Options, Battery Type [9418].
2.
Select the battery type.
9.19.
Report Fail Trouble
If the Report Fail Trouble option is enabled, failure to report an event displays System Trouble on the LCD display.
Report Fail Trouble is displayed after the control system has exhausted all message attempts and report cycles when
trying to report the event. To restore a System Trouble condition caused by failure to report, press
until you have
scrolled through the entire system trouble list. If the Report Fail Trouble is disabled, failure to report an event does not
cause a system trouble condition.
To program the Report Fail Trouble option:
1.
From the Programming menu, select System Options, Rep. Fail Trb. [9419].
2.
Select Enabled or Disabled.
9.20.
Immediate Arming from WUApp
If immediate arming from WUApp is enabled, all WEB Arm commands received are executed immediately regardless
of the programmed Exit Delay – see p. 43,
8.1 Entry/Exit Delay. If disabled, the ARM commands will be executed with
the programmed Exit Delay.
1.
From the Programming menu, select System Options, WEB Immed. Arm [9420].
2.
Select Enabled or Disabled.
9.21.
T014A Standard
To turn on the T014A functionality, perform the following procedure:
For this functionality to function, the EN-50131 standard must be chosen.
1.
From the Programming menu, select System Options, T014A, Enable T014A [94211].
2.
Select Enable or Disable.
To reset messages:
1.
From the Programming menu, select System Options, T014A, Message Reset [94212].
The system Prompts: "Messages Reset OK?"
2.
Press "'
√ʹʺ to reset the messages.
9.22.
Alarm Memory Reset
The Alarm Memory Reset feature enables the installer to enable or disable the alarm reset procedure. This procedure, if
enabled, ensures that once an armed control system has been disarmed all alarm LED indicators are automatically
deactivated (reset).
To set the alarm memory reset feature; perform the following procedure:
1.
From the Programming menu, select System Options, Al. Mem. Reset [9422].
2.
Select Enable or Disable.
Содержание iconnect
Страница 79: ...Appendix A Menu Structure iConnect Installation Manual 75 ...
Страница 80: ...Appendix A Menu Structure iConnect Installation Manual 76 ...
Страница 81: ...Appendix A Menu Structure iConnect Installation Manual 77 ...
Страница 82: ...Appendix A Menu Structure iConnect Installation Manual 78 ...
Страница 83: ...Appendix A Menu Structure iConnect Installation Manual 79 ...
Страница 84: ...Appendix A Menu Structure iConnect Installation Manual 80 ...