B: Modbus Map and Retrieving Logs
Doc# E149721 MM-21
Electro
Industries/GaugeTech
The Leader In Power Monitoring and Smart Grid Solutions
Description (Note 1)
Format
Range (Note 6)
Units or Resolution
Comments
# Reg
Modbus Address
Hex
Decimal
read/write except as noted
C34C
-
C34D
49997 -
49998 Log Retrieval Session Duration
UINT32
0 to 4294967294
4 msec
0 if no session active; wraps around after max count
2
C34E
-
C34E
49999 -
49999 Log Retrieval Session Com Port
UINT16
0 to 4
0 if no session active, 1-4 for session active on COM1 -
COM4
1
C34F
-
C34F
50000 -
50000 Log Number, Enable, Scope
UINT16
bit-mapped
nnnnnnnn esssssss
high byte is the log number (0-system, 1-alarm, 2-
history1, 3-history2, 4-history3, 5-I/O changes, 11-
waveform, (11 reserved for future use)
e is retrieval session enable(1) or disable(0)
sssssss is what to retrieve (0-normal record, 1-
timestamps only, 2-complete memory image (no data
validation if image)
1
C350
-
C350
50001 -
50001 Records per Window or Batch, Record Scope
Selector, Number of Repeats
UINT16
bit-mapped
wwwwwwww snnnnnnn
high byte is records per window if s=0 or records per
batch if s=1, low byte is number of repeats for function 35
or 0 to suppress auto-incrementing; max number of
repeats is 8 (RTU) or 4 (ASCII) total windows, a batch is
all the windows
1
C351
-
C352
50002 -
50003 Offset of First Record in Window
UINT32
bit-mapped
ssssssss nnnnnnnn
nnnnnnnn nnnnnnnn
ssssssss is window status (0 to 7-window number, 0xFF-
not ready); this byte is read-only.
nn…nn is a 24-bit record number. The log's first record is
latched as a reference point when the session is enabled.
This offset is a record index relative to that point. Value
provided is the relative index of the whole or partial record
that begins the window.
2
C353
-
C3CD
50004 -
50126 Log Retrieve Window
UINT16
see comments
none
mapped per record layout and retrieval scope, read-only
123
Block
Size:
130
read
only
Alarm Log Status Block
C737
-
C738
51000 -
51001 Log Size in Records
UINT32
0 to 4,294,967,294
record
2
C739
-
C73A
51002 -
51003 Number of Records Used
UINT32
1 to 4,294,967,294
record
2
C73B
-
C73B
51004 -
51004 Record Size in Bytes
UINT16
14 to 242
byte
1
C73C
-
C73C
51005 -
51005 Log Availability
UINT16
none
0=available,
1-4=in use by COM1-4,
0xFFFF=not available (log size=0)
1
C73D
-
C73F
51006 -
51008 Timestamp, First Record
TSTAMP
1Jan2000 - 31Dec2099
1 sec
3
C740
-
C742
51009 -
51011 Timestamp, Last Record
TSTAMP
1Jan2000 - 31Dec2099
1 sec
3
C743
-
C746
51012 -
51015 Reserved
Reserved
4
Individual Log Status Block Size:
16
C747
-
C756
51016 -
51031 System Log Status Block
16
C757
-
C766
51032 -
51047 Historical Log 1 Status Block
16
C767
-
C776
51048 -
51063 Historical Log 2 Status Block
16
C777
-
C786
51064 -
51079 Historical Log 3 Status Block
16
C787
-
C796
51080 -
51095 Reserved
16
C7A7
-
C7B6
51112 -
51127 Waveform Capture Log Status Block
same as alarm log status
block
16
Block
Size:
128
Log Retrieval Section
Log Retrieval Block
Log Status Block
same as alarm log status block
same as alarm log status block
same as alarm log status block
same as alarm log status block
End of Map