![Electro Industries Shark 200S Скачать руководство пользователя страница 109](http://html.mh-extra.com/html/electro-industries/shark-200s/shark-200s_installation-and-operators-manual_2379717109.webp)
Doc
#
E149721
6 - 13
6: Ethernet Configuration
Electro
Industries/GaugeTech
The Leader In Power Monitoring and Smart Grid Solutions
Electro
Industries/GaugeTech
The Leader In Power Monitoring and Smart Grid Solutions
wise (unicast) encryption. For example, for CCMP+TKIP, CCMP is the pairwise
encryption and TKIP is the group encryption. CCMP is the default for WPA2.)
TX Data rate: 0=fixed, 1=auto fallback <1> ? 1
TX Data rate: 0=1, 1=2, 2=5.5, 3=11, 4=18, 5=24, 6=36, 7=54 Mbps <7> ?
Enter data transmission rate, e.g., 7 for 54Mbps.
Minimum Tx Data rate: 0=1, 1=2, 2=5.5, 3=11, 4=18, 5=24, 6=36,
7=54 Mbps <0> ? 0
Enable Power management <N> ? Y
Enable Soft AP Roaming <N> ? N
Max Failed Packets (6-64, 255=disable) <6>? 6
Security Settings (7)
Disable SNMP <N> ? N
SNMP Community Name <public>: (You can enter an SNMP community name here.)
Disable Telnet Setup <N> ? N (If you change this setting to Y, you will not be able to
use Telnet to re-configure the Network card once you save the settings, without reset-
ting the Network card, as shown in Section 6.4. However, you may want to disable
Telnet setup and Port 77FEh to prevent users from accessing the setup from the net-
work.)
Disable TFTP Firmware Update <N> ? N
Disable Port 77FEh <N> ? N (For security purposes, you may want to disable Telnet
setup and Port 77FEh to prevent users from accessing the setup from the network.)
Enable Enhanced Password <N> ? N
Exiting the screen
CAUTION!
DO NOT PRESS 'D': that will restore the Default Settings.
Press 'S' to Save the settings you've entered.