66
66
EN
ESIM384 Installation and Configuration Manual v1.1
15. StaY MoDE
Stay mode allows the user to arm and disarm the alarm system without leaving the secured area. If the zones with Stay attribute enabled
are violated when the system is StAY-armed, no alarm will be caused. typically, this feature is used when arming the system at home before
going to bed.
the system can be StAY-armed under the following conditions:
•
If a Delay-type zone is NOt violated during exit delay and a zone (-s) with Stay attribute enabled exists, the system will arm in Stay
mode. When arming the system in Stay mode under this condition, one of the available arming methods must be used that provide exit
delay. For more details on these methods, please refer to
13. EXIt anD EntrY DElaY.
•
the system will instantly arm in Stay mode when using one of the following methods.
arm the system in
Stay mode
EKB2
Menu path:
Non-partitioned system:
P2
→
uumm
→
OK
Partitioned system:
P2
→
uumm
→
OK
→
[p] part-name
→
OK
Value:
uumm
– 4-digit user/master code;
p
– partition number, range – [1... 4];
part-name
– up
to 15 characters partition name.
EKB3/
EKB3W/
EWKB4
Press the key and enter user/master:
uumm
Value:
uumm
– 4-digit user/master code.
Example:
1111
EWK1/
EWK2
this operation may be carried out from the wireless keyfob if pre-assigned using the PC run-
ning
ELDES Configuration
software.
When one or more system partitions are successfully armed in Stay mode, eKB2 keypad will display icon in the home screen view.
notE for EKB3/EKB3W/EWKB4:
the Configuration mode must be deactivated, when Stay-arming the system.
notE:
the system can be armed in Stay mode, only if there is at least one zone with Stay attribute enabled.
notE:
Stay mode is not supported by virtual zones.
notE:
the system can also be instantly StAY-armed using eLDeS Cloud Services.
For more details on how to enable Stay attribute for zone, please refer to
14.6. Zone attributes
.