24
24
EN
ESIM384 Installation and Configuration Manual v1.1
3. InStallatIon
When professional installation, OeM integration or assembly by a third-party is expected, the installation instructions and assembly re-
quirements approved for equipment approval must be provided to the integrators to clearly identify the specific requirements necessary
to maintain RF exposure compliance. the grantee of a transmitter, typically the manufacturer, is responsible for ensuring installers and
integrators have a clear understanding of the compliance requirements by including the required instructions and documentation with
the product and, if necessary, to provide further support to fulfil grantee responsibilities for ensuring compliance. the integrators must
be fully informed of their obligations and verify the resolution of any issues and concerns with each transmitter manufacturer or grantee.
•
the system can be installed in a metal or non-flammable cabinet only. For a convenient installation, Me1 metal cabinet is highly recom-
mended. the metal cabinet must always be grounded as well as eSIM384 system’s PCB by connecting one of the COM terminals to the
Pe contact of the metal cabinet.
•
For the connection of 230V transformer, use 3x0.75 mm
2
1 thread double isolated cable. 230V power supply cables must not be
grouped with low voltage cable group.
•
For the connection of auxiliary and BeLL outputs, use 2x0.75 mm
2
1 thread unshielded cable of up to 100m (328.08ft) length.
•
For the connection of zone/PGM output connectors, use 0.50 mm
2
1 thread unshielded cable of up to 100m (328.08ft) length.
SYStEM InStallatIon In ME1 MEtal CaBInEt anD EnCloSUrE CoMPonEntS
TRANSFORMER
AC/DC
COM
FUSE
N L
18V
AC230V
17
fUSE
CoM
aC/DC
18V
n
l
Fuse
315mA tamper transformer
Pe
terminal
Common
terminal
Main power
supply
terminal
AC/DC Main
power
wire
GND wire 230V
wire
AC
voltage Null
Phase