19
19
EN
ESIM384 Installation and Configuration Manual v1.1
notE:
the system does NOt support 2-wire smoke detectors.
type 3
example of motion detector wiring
Z1
CO
M
COM
AUX+
AU
X-
+Vin
GND
NC
TAMP
5,6 kΩ
3,3 kΩ
Z
COM
NO
EOL 5.6K
Z
COM
NC
EOL 5.6K
Z
COM
NC
NC
5.6K
3.3K
Z
COM
NC
3.3K
EOL 5.6K
TAMPER
Z
COM
NC
3.3K
NC
5.6K
EOL 5.6K
TAMPER
5
8-Zone mode: tamper
and 5,6KΩ end-of-line
resistor and 3,3KΩ
end-of-line resistor
with normally closed
contact.
type 4
example of magnetic door contact (Z1) and glass break sensor (Z9) wiring
AUX+
+Vin
AU
X-
GND
COM
COM
NC
NC
CO
M
Z1
5,6 kΩ
3,3 kΩ
Magnet
Z
COM
NO
EOL 5.6K
Z
COM
NC
EOL 5.6K
Z
COM
NC
NC
5.6K
3.3K
Z
COM
NC
3.3K
EOL 5.6K
TAMPER
Z
COM
NC
3.3K
NC
5.6K
EOL 5.6K
TAMPER
6
AtZ mode: 5,6KΩ
end-of-line resistor
and normally closed
contact with 3,3KΩ
end-of-line resistor
and normally closed
contact
type 5
example of motion detector (Z1) and magnetic door contact (Z9) wiring
Z
COM
NO
EOL 5.6K
Z
COM
NC
EOL 5.6K
Z
COM
NC
NC
5.6K
3.3K
Z
COM
NC
3.3K
EOL 5.6K
TAMPER
Z
COM
NC
3.3K
NC
5.6K
EOL 5.6K
TAMPER
Z1
CO
M
COM
COM
AUX+
AU
X-
+Vin
GND
NC
NC
TAMP
5,6 kΩ
5,6 kΩ
3,3 kΩ
Magnet
AtZ mode: tamper,
5,6KΩ end-of-line
resistor, 5,6KΩ
end-of-line resistor
with normally closed
contact and 3,3KΩ
end-of-line resistor
with normally closed
contact.
7
See also
14.3. 8-Zone Mode