60
60
EN
ESIM384 Installation and Configuration Manual v1.1
zone with the Force attribute enabled remains violated until the exit delay expires, it will be ignored. Once the system is partially armed
followed by zone restore, the violation of this zone will no longer be ignored and the zone will operate according to the determined
type. For more details on zone types, please refer to
14.5. Zone type Definitions
.
•
Shared
– this attribute determines whether a zone, assigned to multiple partitions, will cause an alarm or not in the associated armed
partition if violated. If a zone with the Shared attribute enabled is violated when at least one of the associated partitions is disarmed,
the alarm will not be caused. Once the system is armed in all of the associated partitions, the zone with Shared attribute enabled will
operate according to the determined type. typically, this attribute is used for shared areas, such as corridors.
•
Delay, s
– this attribute determines the zone sensitivity level by delay time (by default – 15 seconds). If the zone remains triggered until the
delay time expires, the zone is considered violated. this attribute does not apply to wireless zones, keypad zones and virtual zones.
•
Cross-Zone/Intelli-Zone
is a method used to prevent false alarms. the system will not cause an alarm unless two associated zones
are violated within a specified time period, known as Alarm Confirmation timeout. By associating a certain zone to itself, the system
would cause an alarm only if the zone has been violated repeatedly within the Alarm Confirmation timeout. this feature operates with
all zone categories including virtual zones.
•
Delay becomes Instant in Stay mode
– this attribute determines whether or not any Delay type zone will operate as Instant type
zone when the system is armed in the Stay mode. When the system is fully armed, the Delay type zone will operate normally. For more
details on Delay and Instant zone types, please refer to
14.5. Zone type Definitions
.
•
Chime
– this feature is used to emit 3 short beeps from the keypad buzzer whenever any Delay type zone is violated while the system
is disarmed. typically, the feature is used for designated exit/entry doors to indicate the opening of the doors.
•
Bell
- this attribute operates identically as Chime and applies to eKB3W/eWKB4 keypad only.
•
alarm Count to Bypass
– this attribute determines a number of times the zone can be violated until it is automatically bypassed. It
can be assigned to Interior Follower, Instant, Delay and Instant Silent zone types only. Alarm Count to Bypass becomes inactive once
the Stay attribute is enabled on the same zone. For more details on zone bypassing and how to activate a bypassed zone, please refer
to
14.7. Bypassing and activating Zones
.
notE:
Due to battery power saving reasons, eKB3W/eWKB4 wireless keypad buzzer will not sound if the Bell attribute is not enabled and the
violated Delay type zone is not of the associated eKB3W/eWKB4 wireless keypad. For more details on eKB3W/eWKB4 wireless keypad, please
refer to
19.5. EKB3W/EWKB4 – Wireless lED Keypad.
Enable Stay attribute
for individual zone
EKB2
Menu path:
On-board zone:
OK
→
iiii
→
OK
→
ZONeS
→
OK
→
ONBOARD ZONeS
→
OK
→
ZONe 1... 16
→
OK
→
StAY
→
OK
→
eNABLe
→
OK
Wireless zone :
OK
→
iiii
→
OK
→
WIReLeSS ZONeS
→
OK
→
WIReLeSS ZONeS 1... 4
→
OK
→
WIReLeSS ZONe 13... 80
→
OK
→
StAY
→
OK
→
eNABLe
→
OK
Keypad zone:
OK
→
iiii
→
OK
→
ZONeS
→
OK
→
KeYPAD ZONeS
→
OK
→
1St... 4tH KePAD
ZONe
→
OK
→
StAY
→
OK
→
eNABLe
→
OK
ePGM1 zone:
...
→
ePGM1 ZONeS 1-16... ePGM1 ZONeS 17-32
→
OK
→
1...8. ePGM1 ZONe 1...
32
→
OK
→
StAY
→
OK
→
eNABLe
→
OK
Value:
iiii
– 4-digit installer code.
EKB3/
EKB3W/
EWKB4
Enter parameter 56, zone number and parameter status value:
56 nn 1 #
Value:
nn
– zone number, range – [01... 80].
Example:
56041#
ElDES
Config-
uration
software
this operation may be carried out from the PC using the
ELDES Configuration
software.
Disable Stay attribute
for individual zone
EKB2
Menu path:
On-board zone:
OK
→
iiii
→
OK
→
ZONeS
→
OK
→
ONBOARD ZONeS
→
OK
→
ZONe 1... 16
→
OK
→
StAY
→
OK
→
DISABLe
→
OK
Wireless zone:
OK
→
iiii
→
OK
→
WIReLeSS ZONeS
→
OK
→
WIReLeSS ZONeS 1... 4
→
OK
→
WIReLeSS ZONe 13... 80
→
OK
→
StAY
→
OK
→
DISABLe
→
OK
Keypad zone:
OK
→
iiii
→
OK
→
ZONeS
→
OK
→
KeYPAD ZONeS
→
OK
→
1St... 4tH KeYPAD
ZONe
→
OK
→
StAY
→
OK
→
DISABLe
→
OK
ePGM1 zone:
...
→
ePGM1 ZONeS 1-16... ePGM1 ZONeS 17-32
→
OK
→
1...8. ePGM1 ZONe 1...
32
→
OK
→
StAY
→
OK
→
DISABLe
→
OK
Value
:
iiii
– 4-digit installer code.
EKB3/
EKB3W/
EWKB4
Enter parameter 56, zone number and parameter status value:
56 nn 0 #
Value:
nn
– zone number, range – [01... 80].
Example:
56190#