107
107
EN
ESIM384 Installation and Configuration Manual v1.1
EKB3/
EKB3W/
EWKB4
Enter parameter 25/21/55, event number, user phone number slot and parameter
status value:
User phone number:
25 07 up 1 #
SMS text message to all users simultaneously:
21 07 1 #
SMS delivery report:
55 07 1 #
Value:
up
- user phone number slot, range - [01... 10].
Example:
2107021#
ElDES
Config-
uration
software
this operation may be carried out from the PC using the
ELDES Configuration
software.
For more details on how
Send SMS text message to all users simultaneously
and
SMS Cascade
parameters affect the SMS text massage
transmission, please refer to
27. SYStEM notIfICatIonS
.
notE:
In order to view the backup battery voltage, resistance, please refer to Diagnostic Management feature available on
ELDES Configu-
ration
software.
21.2. Mains Power Status Monitoring
If the household electricity is unstable in the system installation area, the system may temporally lose its power supply and continue oper-
ating on the backup battery power. the system supervises the mains power and notifies the user by SMS text message as well as indicates
system fault condition on the keypad (see
29. InDICatIon of SYStEM faUltS
) when the mains power is lost. When the mains power
restores, the system will notify the user by SMS text message and the keypad will no longer indicate system fault.
By default, system notification by SMS text message regarding mains power status is enabled. to disable/enable this notification, please
refer to the following configuration methods.
Disable mains
power loss/restore
notification
EKB2
Menu path:
User phone number:
OK
→
iiii
→
OK
→
SMS MeSSAGeS 1
→
OK
→
MAIN POWeR L/R
→
OK
→
GSM USeR 1... 10
→
OK
→
DISBLe
→
OK
SMS text message to all users simultaneously:
...
→
MAIN POWeR L/R
→
OK
→
SMS tO ALL
→
OK
→
DISABLe
→
OK
SMS delivery report:
...
→
MAIN POWeR L/R
→
OK
→
SMS RePORt
→
OK
→
DISABLe
→
OK
Value:
iiii
– 4-digit installer code.
EKB3/
EKB3W/
EWKB4
Enter parameter 25/21/55, event number, user phone number slot and parameter
status value:
User phone number:
25 04 up 0 #
SMS text message to all users simultaneously:
21 04 0 #
SMS delivery report:
55 04 0 #
Value:
up
- user phone number slot, range - [01... 10].
Example:
2504050#
ElDES
Config-
uration
software
this operation may be carried out from the PC using the
ELDES Configuration
software.
Enable mains
power loss/restore
notification
EKB2
Menu path:
User phone number:
OK
→
iiii
→
OK
→
SMS MeSSAGeS 1
→
OK
→
MAIN POWeR L/R
→
OK
→
GSM USeR 1... 10
→
OK
→
eNABLe
→
OK
SMS text message to all users simultaneously:
...
→
MAIN POWeR L/R
→
OK
→
SMS tO ALL
→
OK
→
eNABLe
→
OK
SMS delivery report:
...
→
MAIN POWeR L/R
→
OK
→
SMS RePORt
→
OK
→
eNABLe
→
OK
Value:
iiii
– 4-digit installer code.
EKB3/
EKB3W/
EWKB4
Enter parameter 25/21/55, event number, user phone number slot and parameter
status value:
User phone number:
25 04 up 1 #
SMS text message to all users simultaneously:
21 04 1 #
SMS delivery report:
55 04 1 #
Value:
up
- user phone number slot, range - [01... 10].
Example:
2514091#
ElDES
Config-
uration
software
this operation may be carried out from the PC using the
ELDES Configuration
software.
By default, mains power loss and restore delay are 30 and 120 seconds respectively. to set a different mains power loss and restore delay