38
10.12 Unable to see capsule
record logs (displays zero
capsules docked)
1. Looking at empty capsule
log placeholders. There
are 60 place holders.
a. Press F5 (pg up) or F10
(pg dn) until capsule
numbers begin appearing.
10.13 Unable to save
date/time changes.
1. Not pressing save key
a. Press F5 to save the
change before exiting out
of the screen.
1. Lid not closed
a. Close lid
2. Lid magnet is missing
a. Replace lid magnet
3. Hot or cold water valve
failure.
a. Replace hot or cold water
valve.
4. Main water valve strainer
clogged.
a. Clean strainer.
5. Safety switch not actuated
(display will read “replace
product caps now”).
a. Check switch for free
movement. Replace if
necessary.
10.14 No water spray
6. Tank not at low level or
below.
a. Replace capsule only
when amber “replace
product” light is on (tank
at low level) and
dispenser calls for new
capsule.
10.15 Display shows
“F1 ; Formula 1 Pump AUX
to Washer #X”
And no use solution is
delivered to washer X.
1. Washer Signal #1 (for use
solution) is wired incorrectly to
Signal #2 (for Finish product).
a. Rewire signal from washer