Line 1: This screen allows the programming data for Washer #1, Formula #1
(W1F1) for Auxiliary product.
HvySwToTest: TMs can use the Heavy Soil Signal switch on the User Interface
Module (mounted at washer #1) to trigger a dose of Auxiliary product to a
graduated cylinder to verify the programmed amount.
Note: To verify the programmed amount for Formula 1, the Selector Switch on
the User Interface module needs to be set to the Formula 1 position.
Line 2: the delay amount can be programmed in increments of 1 second (1 – 99).
Note the cursor is a solid underline bar under the number 5. To edit/change the
Delay amount, press <Ent>. Note the cursor is now changed to a blinking darker
square, ready to accept the new data. Use the soft keys to enter the numbers as
described in previous sections, and use <Right> or <Left> arrow keys to move
between data fields.
Once the delay is entered correctly, press <Ent> to save the new value. NOT
pressing <Ent> will discard the changes and default back to the factory settings.
Use the <Right> arrow key to move to the Pump (PMP) amount. This amount
can be programmed in fluid-ounces (Fl. oz) in increments of 0.1 oz (0.0 – 20.0).
The decimal point is pre-programmed for that data field, i.e. there is no need to
enter the amounts using the decimal point. For example, if the desired amount is
1.8 oz, key in 18, then press <Ent> key.
To enter new amounts, press <Ent> key. Note the cursor is now changed to a
blinking darker square, ready to accept the new data. Use the soft keys to enter
the numbers as described in previous sections, and use <Right> or <Left> arrow
keys to move between data fields.
Once the amount is entered correctly, press <Ent> to save the new value. NOT
pressing <Ent> will discard the changes and default back to the factory settings.
Then press <Esc> to exit to the previous menu.
Selecting
“Wash1 Form2 Deterg” will display the following screen:
W1 F2 Det(HvySwToTest
DLY: 5 s. Pump: 25.0 oz
Pressing <Esc> key will exit to the previous menu screen, keeping the default
settings.
Line 1: This screen allows the programming data for Washer #1, Formula #2
(W1F2).
HvySwToTest: TMS can use the Heavy Soil Signal switch on the User Interface
Module (mounted at washer #1) to trigger a dose of detergent to a graduated
cylinder to verify or test the programmed amount.
Note: To verify the programmed amount for Formula 2, the Selector Switch on
the User Interface module needs to be set to the Formula 2 position.
Line 2: the delay amount can be programmed in increments of 1 second (1 – 99).
Note the cursor is a solid underline bar under the number 5. To edit/change the
Delay amount, press <Ent>. Note the cursor is now changed to a blinking darker