15
in the installation kit – one for each user interface. 25’ is the
recommended max cable length. Use the 50’ cable only when necessary.
1. Route the cable from the Washer Interface Module to the back of the
dispenser and connect to communication port. (Refer to fig. 5.3.1)
Note: It is helpful to label the communication cable for
identification.
2. The communication cables are keyed to fit in one way only. Insert
cable gently into the comm port of the washer interface module. If the
cable connector does not fit into port easily, rotate the cable 180
degrees and try again.
Do not force cable.
6.0 Start up
6.1 Dock product capsule
1. Lift
dock
lid.
2. Remove and discard cap on new product capsule.
3. Dock new capsule.
4. Close
lid.
5. Press Start key.
Water will now be sprayed into the capsule until the tank level reaches the high
level. The dispenser will automatically activate the hot and cold water valves to
alternate the water spray between hot and cold water (the hot water valve will
always be turned on first). The water valves are alternated to provide effective
capsule rinse-out while maintaining a tank sump temperature below 105
º
F.
The water pressure regulators are factory-set to 10 psi (
±
0.5 psi) when valve is
open. If adjustment is necessary, adjust the hot and cold water pressure
regulators on the regulator mounting plate to read 10 psi when in flow (see figure
5.3.1). You should only adjust the hot regulator when the hot water valve is
active. You should only adjust the cold water regulator when the cold water
valve is active. The entire capsule contents will be rinsed into the tank. Total
time to fill the tank will be 10-30 minutes. The dispenser will begin to recirculate
the solution and continues to do so automatically every hour.
6.2 Prime product-delivery tubes
See “Prime” section of quick start programming guide (Section 8)
6.3
Calibrate dispenser
See “Calibrate” section of quick start programming guide (Section 8)
6.4 Program formula amounts
See
Formula Progr. Menu
(page 31 of the Appendix) or the attached
programming flow chart