V&T Technologies Co., Ltd.
http://www.ecodrivecn.com
Chapter 6 Parameter Description
83
10V
2V
0
Before calibration
After calibration
Output value
per-unit value
AO1 gain 1: Negative;
AO1bias 0: Positive;
20%
100%
10V
8V
0
Before calibration
After calibration
Output value
per-unit value
AO1 gain 1: Negative;
AO1 bias 0: Positive;
80% 100%
AO1 terminal output voltage
AO1 terminal output voltage
Fig.6
−2
6 AO1 Characteristics Curve
−Kx+b
Fig.6
−2
7 AO1 Characteristics Curve
−Kx+b
Note: When the analog output gain is set to negative value and the bias is also negative, the AO output
will be limited to 0V automatically.
This function code determines Y1 and relay output signal type selection (level or pulse).
Note: The life of relay is about 10 million times, frequent open and close will be shortened use of time.
Display of operation panel
Unit place
Y1 terminal: 0:Level signal; 1:Pulse signal
Tens place
Reserved
Hundreds place
Relay terminal: 0: Level signal; 1:Pulse signal
Terminal delay time on the level or the pulse output signals are valid, terminal pulse width defines pulse
signal the effective pulse hold time.
Figure 6
−
27 in the Yi on behalf of Y1, relay terminal, in order to keep the waveform consistent before
delay and after delay, need to ensure that the output signal width> Yi terminal delay setting, if the output
signal width <Yi terminal delay setting, the signal will be ignored.
P7.11
Output signal type
000 ~ 101(000)
P7.16
Relay terminal delay time
0.0~999.9s % (0.0s)
P7.17
Relay terminal pulse width
0.0~999.9s % (0.0s)
P7.12
Y1 terminal delay time
0.0~999.9s % (0.0s)
P7.13
Y1 terminal pulse width
0.0~999.9s % (0.0s)