V&T Technologies Co., Ltd.
http://www.ecodrivecn.com
Appendix B Control Mode Setting Process
127
Open loop setting process (continued)
Deceleration stop?
First DC braking after
begin to run from the startup
frequency?
Begin to run from the startup
frequency
Setting P3.00=0
Setting startup frequency
P3.03 and startup frequency
retention time P3.04
Free stop?
Anti-reverse?
Setting P3.09=1
DC braking stop, setting P3.05=2, setting
P3.06, P3.07 and P3.08 properly
(For the meaning, refer to
Chapter 6 Parameter Description)
Dynamic braking?
Setting PA.09=0
Setting P3.00=1 DC
braking current
P3.01 and retention
time of braking keep
P3.02
Rotation speed tracing startup,
setting P3.00=2
Setting P3.05=0
Setting P3.05=1
Setting P3.09=0
Setting PA.09=1
END
N
Y
N
Y
N
Y
N
Y
N
Y
N
Y
Select multi acceleration/
deceleration time?
Select function of X terminal
acceleration/deceleration time
?
(For details, refer to the function
description of P5.00 to P5.06 in
Chapter 6)
Setting correct
P4.09
~
P4.14
Setting P0.08 and P0.09
N
Y
JOIN THE PAGE