Chapter 6 Parameter Description
74
X1(X2) Signal
X1(X2) signal after
delay
X1(X2) terminal delay time t
X1(X2) signal pulse width t
w2
X1(X2) signal
before delay
Time
X1(X2) signal pulse width t
w1
Fig.6
−
13 X1/X2 terminal delay
Note: The signal can be identified only when the X1/X2 signal pulse width larger than X1/X2 terminal
delay time. See Fig.6
−
13, t
w1
can be identified and t
w2
will be ignored.
P5.11 is used to set the mode of controlling the startup and stop of the inverter with FWD and REV
terminals in the terminal running command reference mode.
0: Two line 1;
COM
FWD
REV
K1
K2
变
频
器
Inverter
COM
FWD
REV
K1
K2
变
频
器
Inverter
Fig.6
−
14 Two
−
line running mode 1
1: Two line 2;
COM
FWD
REV
K1
K2
变
频
器
Inverter
COM
FWD
REV
K1
K2
变
频
器
Inverter
Fig.6
−
15 Two
−
line running mode 2
FWD
REV
Start
−
up and
stop
command
0
0
Stop
0
1
Reverse
rotation
1
0
Forward
rotation
1
1
Stop
FWD
REV
Start
−
up and
Stop
0
0
Stop
0
1
Stop
1
0
Forward
rotation
1
1
Reverse
rotation
P5.11
Startup/stop mode Selection
0 ~ 3(0)