Appendix B Control Mode Setting Process
128
3. Setting Process for Closed Loop
START
Parameter identification (for details,
refer to setting process for parameter
auto-tuning under V/F control in
appendix B)
Select process close loop main reference
mode P1.02 (For details, refer to the function
description of P1.02 in Chapter 6)
Select process close loop reference main
and auxiliary relation calculation P1.04
(For details, refer to the function
description of P1.04 in Chapter 6)
Select function of X control
terminal (For details, refer to
the function description of
P5.00 to P5.06 in Chapter 6)
Select process close loop auxiliary
reference mode P1.03?(For details, refer
to the function description of P1.03 in
Chapter 6)
Multi digital voltage reference?
Multi voltage reference function of terminal X?
(For details, refer to the function description of
P5.00 to P5.06 in Chapter 6)
Setting correct
P4.15
~
P4.21
Running command Keypad
control
Running command Terminal
control
Setting P0.06=1
Setting P0.06=0
Setting P0.07 according to
running direction
(0: Forward; 1: Reverse)
Running command communicate
control, setting P0.06=2
Select Analog
channel ?
Select Analog channel ?
Setting P6.00
~
P6.20
(For details, refer to the function
description of P6.00 to P6.20 in
Chapter 6)
Setting P6.00
~
P6.20
(For details, refer to the
function description of P6.00
to P6.20 in Chapter 6)
N
N
Y
Y
Y
N
N
N
NEXT PAGE
Analog value feedback?
P0.03=1
Select process close loop main feedback
mode P1.05(For details, refer to the
function description of P1.05 in Chapter
6)
Close loop auxiliary feedback?
Select process close auxiliary feedback
mode P1.06 (For details, refer to the
function description of P1.06 and P6.00
to P6.20 in Chapter 6)
Select process close loop main and
auxiliary relation calculation p1.07 (For
details, refer to the function description
of P1.07 in Chapter 6)
Process close loop relative function
code setting (For details, refer to the
function description of
GROUP P8 in Chapter 6)
N
Y
Y
Y
N
Y
Setting P6.00
~
P6.20
(For details, refer to the function
description of P6.00 to P6.20 in
Chapter 6)
Select Analog channel ?
Y
N
Close loop
auxiliary reference ?