Chapter 5 List of Parameters
47
Function
code
number
Function code name
Factory
setting
Setting range Unit Property
Function code selection
User
setting
running process
LED hundreds place: Input power error
LED thousands place: Output phase
failure
0: Fault is not shileded, stopped upon
fault;
1: Fault is not shielded, non
−
stop upon
fault;
2: Fault is shielded, no alarm and no
stop
PA.17
Fault shield and alarm
attribute setting 2
0000
0000 ~ 2222
/
×
LED ones place: EEPROM error
LED tens place: Relay contact
open/close failure
LED hundreds place: Temperature
sampling disconnection
LED thousands place: Reserved
PA.18
Fault shield and alarm
attribute setting 3
2000
0000 ~ 2222
/
×
LED ones place: +10V output error
LED tens place: Analog input error
LED hundreds place: Motor over
temperature (PTC)
LED thousands place: Communication
failure 1(operation panel 485)
0: Fault is not shileded, stopped upon
fault;
1: Fault is not shielded, non
−
stop upon
fault;
2: Fault is shielded, no alarm and no
stop
PA.20
Fault locking function
selection
0
0 ~ 1
/
×
0: Fault is not locked;
1: Fault is locked
PA.21
Automatic reset times
0
0 ~ 20
/
×
0 ~ 20
PA.22
Automatic reset interval
2.0
2.0 ~20.0
s
×
2.0 ~ 20.0s
Group Pb Enhanced Function Parameter
Pb.00
Hopping frequency 1
lower limit
0.00
0.00 ~ 300.00
Hz
×
Upper / lower frequency limit (P0.13 ~
P0.14)
Pb.01
Hopping frequency 1
upper limit
0.00
0.00 ~ 300.00
Hz
×
Upper / lower frequency limit (P0.13 ~
P0.14)
Pb.02
Hopping frequency 2
lower limit
0.00
0.00 ~ 300.00
Hz
×
Upper / lower frequency limit (P0.13 ~
P0.14)
Pb.03
Hopping frequency 2
upper limit
0.00
0.00 ~ 300.00
Hz
×
Upper / lower frequency limit (P0.13 ~
P0.14)
Pb.04
Hopping frequency 3
lower limit
0.00
0.00 ~ 300.00
Hz
×
Upper / lower frequency limit (P0.13 ~
P0.14)
Pb.05
Hopping frequency 3
upper limit
0.00
0.00 ~ 300.00
Hz
×
Upper / lower frequency limit (P0.13 ~
P0.14)
Pb.06
Single step under
without integral function
0.1
0.1~10.00
Hz
○
0.1~10.00 Hz
Pb.07
Magnification selection
00
00 ~ 11
/
×
Ones place: Acceleration /
deceleration time
0: X1;
1: X10
Tens place: Reserved
Pb.08
Operation panel
∧/∨
digital regulating
frequency control
0001
0000 ~ 1221
/
○
Ones place: Action upon power off
0: Save upon power off;
1: Clear upon power off
Tens place: Action upon stopping
0: Hold upon stopping;
1: Clear upon stop;
2: Clear upon standby
Hundreds place:
∧/∨ setting via
operation panel