V&T Technologies Co., Ltd.
http://www.ecodrivecn.com
Chapter 4 Using Instructions of Operation Panel
30
4.4.3 Menu Mode
Menu mode
setting
(P0.02)
Menu mode name
Visible function code range
Operation panel
display
0
Basic menu
See 5.1 for the table of basic menu
function code parameter
bASE
1
Fast menu
Quickly display the menu function
codes in common use
FASt
2
Non
−
leave
−
factory value
function code menu
Only display the function codes
different from the leave
−
factory
values
ndFt
3
Menu of last changed 10
function codes
Display the last changed 10
function codes and P0.02
LASt
Basic menu bASE
Basic menu includes all the function codes mentioned in this user manual. Except for the special
descriptions, all the descriptions of this manual are in this menu mode. See 5.1 for the table of basic
menu function code parameter.
Fast menu FASt
Fast menu includes some common function codes and you can start the inverter by setting only a few
function codes so as to realize the fast application. See 5.2 for the table of fast menu function code
parameter.
Non
−
leave
−
factory value function code menu ndFt
This menu mode is used to search for the function codes different from the leave
−
factory values for the
convenience of understanding the parameter setting.
Menu of last changed 10 function codes LASt
If this menu mode is set, it enters password protection status. Only P0.00 and C0.00 can be viewed. The
recently changed function codes, P0.00 and P0.02 can be viewed only when correct password is entered
into P0.00.
Method of back to basic menu
1.
By editing the function code: Set P0.02=0, then the menu returns to basic menu mode after
bASE is displayed.
2.
By using M key: Define the function of multi
−
function key M as menu switching function, then
press this key to switch the menu mode. Refer to table 4
−
1 for the using method of
multi
−
function key and the meanings of MULTI indicator.
3.
By pressing ESC for a long time: Press ESC and do not release it for more than 5s, then the
menu returns to basic menu mode after bASE is displayed. If bASE is not displayed, this
means the menu is already in basic menu mode.