Chapter 6 Parameter Description
95
The function can be used to manage various actions when some failures occur. When these failures
occur under some special circumstances, inverter shall alarm immediately but not stop. Alarm
information is displayed on the operational panel and even the failure is to be shielded.
Unit place, tens place, hundreds place and thousands place displayed on operational panels from PA.16
to PA.18 can be set:
0: Failure not shielded and alarm and stop during failure.
1: Failure not shielded and alarm but not stop during failure.
2: Failure shielded, neither alarm nor stop.
Note: To change factory
−
setting, please contact with distributor or manufacturer.
PA.16 failure shield and alarm attribute setting 1
Display of operation panel
Unit place
Output short circuit to ground abnormality
Tens place
Power failure abnormality during running
Hundreds place
Input power abnormality
Thousands place
Output phase loss EEPROM abnormality
PA.17 failure shield and alarm attribute setting 2
Display of operational panel
Unit place
EEPROM abnormality
Tens place
Relay contact abnormality
Hundreds place
Temperature sampling disconnection
Thousands place
Reserved
PA.18 Failure shield and alarm attribute setting 3
Display of operational panel
Unit place
Ab10V power supply output
Tens place
Abnormal analog input
Hundreds place
Motor over
−
temperature (PTC)
Thousands place
Abnormal communication1(operational panel 485)
0: Failure lock disabled.
1: Failure lock enabled: Allowing re
−
display defaults occurred upon last power failure after power
−
on
properly run only after resetting failure.
Note:
Whether to output failure indication at the same time is decided by action indication of fault
relay of inverter. Refer to PA.12 instruction.
PA.16
Fault shielded and alarm attribute setup 1
0 ~ 2222(0020)
PA.17
Fault shielded and alarm attribute setup 2
0 ~ 2222(0000)
PA.18
Fault shielded and alarm attribute setup 3
0 ~ 2222(2000)
PA.20
Fault locking function selection
0 ~ 1(0)