Maintenance
417006-2311-0H3-A00
ECI Telecom Ltd. Proprietary
4-25
Replacing I/O Modules
The following procedure is applicable to all I/O modules.
Before you start:
For modules with electrical interfaces that use electrical interface protection via
TPMs, first force a switch to the protection module (IOP) before replacing the
module.
To replace I/O modules:
1.
Mark each cable and fiber connected to the module for identification
purposes.
2.
Disconnect any cables or fibers connected to the module to be replaced.
3.
Open the captive screws fastening the module to the shelf.
4.
Remove the module to be replaced by pulling its handle.
5.
Insert the rear end of the replacement module into the corresponding
module guides.
6.
Push the module in until it mates the chassis connectors. If you feel
resistance before the connectors are mated, pull the module out and repeat
the procedure.
7.
Fasten the module to the shelf by its captive screws.
8.
Reconnect any cables or fibers disconnected in Step 2 to the replacement
module.