Maintenance
XDM-300
Installation
and
Maintenance Manual
4-8 ECI
Telecom
Ltd.
Proprietary
417006-2311-0H3-A00
The system's common components on the ECU300-F are as follows:
|
MODULE selector
|
CHANNEL selector
|
MODULE, 2-digit display
|
CHANNEL, 2-digit display
The ECU300-F components that serve only STM-1 modules are:
|
STM-1 MON monitoring point
|
MON indicator
The monitoring system components on the monitored modules include:
|
MON monitoring point
|
MON indicators
Figure
4-3: Monitoring system interface of a typical module
The monitoring system enables you to monitor traffic passing through a
module. To do so, test equipment is connected to the monitoring point of the
corresponding module, and the module and port are selected by the system's
selectors. As a result, the traffic is closed through the test equipment and the
signal can be viewed, in an eye pattern, on the test equipment display.
Selecting a module
The MODULE selector chooses the monitored module slot number. The
selected module is displayed on the 2-digit display to the right of the selector.
Pressing the selector upward increments the slot number; pressing it downward
decrements the slot number. The selection is cyclic. Possible selections are QA
(I17) and QB (I18) for the aggregate cards (I/O cards), and I1 to I16 for the I/O
modules. If the selected module is an STM-1, the MON indicator on the
ECU300-F lights.