Equipment Installation
XDM-300 Installation and
Maintenance Manual
3-90 ECI
Telecom
Ltd.
Proprietary
417006-2311-0H3-A00
5.
Use a cabling diagram of the site to associate module connectors with the
appropriate DDF connections. Cut excess cable length if necessary.
6.
Connect the cable connector to the corresponding module.
C
AUTION
:
Do not exert excessive tightening torque to
secure the cable connector, as this may damage the module.
7.
Secure the cable connector to the module connector with the two cable
connector screws. Tighten the screws manually; if the screws cannot be
reached with your bare hand, use an adjustable-torque flatblade screwdriver
(maximum blade size 0.6). Set the tightening torque to 40 N cm to 44 N
cm.
Installing an xDDF-21 patch panel
The xDDF-21 is installed above the XDM-300 shelf accessories.
To install an xDDF-21 patch panel:
1.
Route the 2 x 50-pin SCSI cables leading from the PIM2_21 or PIM2_63/B
along the side of the rack to the location where the xDDF-21 patch panel
will be installed.
2.
Before you install the patch panel, connect the SCSI cables leading to the
rear of the xDDF-21 patch panel. The cables are marked J1 and J2 and
should be connected to their respective connectors.
3.
Leaving at least 100 mm free space above the XDM-300 shelf accessories
and below the xDDF-21, attach the patch panel to the rack rails and secure,
using the four supplied screws, washers, and nuts.
4.
Connect the traffic cables to the front of the xDDF-21 patch panel, and
make a note of the appropriate channels on the identification label on the
inside of the panel door.