EDR-5000
IM02602007E
Name
Description
RO-6 X5.RO 2
Signal: Relay Output
RO-6 X5.RO 3
Signal: Relay Output
RO-6 X5.RO 4
Signal: Relay Output
RO-6 X5.RO 5
Signal: Relay Output
RO-6 X5.RO 6
Signal: Relay Output
IEC61850.VirtOut1-I
Module input state: Binary state of the Virtual Output (GGIO)
IEC61850.VirtOut2-I
Module input state: Binary state of the Virtual Output (GGIO)
IEC61850.VirtOut3-I
Module input state: Binary state of the Virtual Output (GGIO)
IEC61850.VirtOut4-I
Module input state: Binary state of the Virtual Output (GGIO)
IEC61850.VirtOut5-I
Module input state: Binary state of the Virtual Output (GGIO)
IEC61850.VirtOut6-I
Module input state: Binary state of the Virtual Output (GGIO)
IEC61850.VirtOut7-I
Module input state: Binary state of the Virtual Output (GGIO)
IEC61850.VirtOut8-I
Module input state: Binary state of the Virtual Output (GGIO)
IEC61850.VirtOut9-I
Module input state: Binary state of the Virtual Output (GGIO)
IEC61850.VirtOut10-I
Module input state: Binary state of the Virtual Output (GGIO)
IEC61850.VirtOut11-I
Module input state: Binary state of the Virtual Output (GGIO)
IEC61850.VirtOut12-I
Module input state: Binary state of the Virtual Output (GGIO)
IEC61850.VirtOut13-I
Module input state: Binary state of the Virtual Output (GGIO)
IEC61850.VirtOut14-I
Module input state: Binary state of the Virtual Output (GGIO)
IEC61850.VirtOut15-I
Module input state: Binary state of the Virtual Output (GGIO)
IEC61850.VirtOut16-I
Module input state: Binary state of the Virtual Output (GGIO)
IEC61850.VirtOut17-I
Module input state: Binary state of the Virtual Output (GGIO)
IEC61850.VirtOut18-I
Module input state: Binary state of the Virtual Output (GGIO)
IEC61850.VirtOut19-I
Module input state: Binary state of the Virtual Output (GGIO)
IEC61850.VirtOut20-I
Module input state: Binary state of the Virtual Output (GGIO)
IEC61850.VirtOut21-I
Module input state: Binary state of the Virtual Output (GGIO)
IEC61850.VirtOut22-I
Module input state: Binary state of the Virtual Output (GGIO)
IEC61850.VirtOut23-I
Module input state: Binary state of the Virtual Output (GGIO)
IEC61850.VirtOut24-I
Module input state: Binary state of the Virtual Output (GGIO)
IEC61850.VirtOut25-I
Module input state: Binary state of the Virtual Output (GGIO)
IEC61850.VirtOut26-I
Module input state: Binary state of the Virtual Output (GGIO)
IEC61850.VirtOut27-I
Module input state: Binary state of the Virtual Output (GGIO)
IEC61850.VirtOut28-I
Module input state: Binary state of the Virtual Output (GGIO)
IEC61850.VirtOut29-I
Module input state: Binary state of the Virtual Output (GGIO)
IEC61850.VirtOut30-I
Module input state: Binary state of the Virtual Output (GGIO)
IEC61850.VirtOut31-I
Module input state: Binary state of the Virtual Output (GGIO)
IEC61850.VirtOut32-I
Module input state: Binary state of the Virtual Output (GGIO)
www.eaton.com