5 Function blocks
5.16 HW, weekly timer
200
Control Relay easy800
11/11 MN04902001Z-EN
www.eaton.com
Examples:
Timing relay = function relay with contacts and coils
Time switch = function relay with contacts
•
Monday to Friday
•
Only on Monday
On and off time
The ON/OFF parameters are used for setting the on and off time.
Operation of the function block
The switching points are defined according to the parameters entered.
MO to FR: on weekdays Mo, Tu, We, Th, Fr
ON 10:00, OFF 18:00: On and off time on each weekday.
MO: Every Monday
ON 10:00: On time
SA: Every Saturday
OFF 18:00: Off time
Switching on working days
The weekly timer HW01 switches on from Mondays to Fridays with channel:
•
A between 6:30 and 9:30
•
B between 17:00 and 22:30
Entry
On and off time
MO
Monday
TU
Tuesday
WE
Wednesday
DO
Thursday
FR
Friday
SA
Saturday
SO
Sunday
--
No day
HW10 A +
>DY1 MO
>DY2 FR
>ON
>OFF
HW14 D +
>DY1 MO
>DY2 --
>ON
>OFF
HW01 B +
>DY1 MO
>DY2 FR
>ON 17:00
>OFF 22:30
HW01 A +
>DY1 MO
>DY2 FR
>ON 06:30
>OFF 09:30
Содержание easy800
Страница 1: ...11 11 MN04902001Z EN replaces AWB2528 1423GB Manual Control Relay 800 4 patpks nycmyn...
Страница 4: ...2...
Страница 16: ...0 About This Manual 0 5 Writing conventions 12 Control Relay easy800 11 11 MN04902001Z EN www eaton com...
Страница 138: ...4 Wiring with 800 4 7 Working with function blocks 134 Control Relay easy800 11 11 MN04902001Z EN www eaton com...
Страница 300: ...7 SmartWire DT 7 4 Errors on the SWD line 296 Control Relay easy800 11 11 MN04902001Z EN www eaton com...
Страница 336: ...10 Diagnostics possibilities 10 4 Transistor output 332 Control Relay easy800 11 11 MN04902001Z EN www eaton com...