5 Function blocks
5.10 CP, comparator
180
Control Relay easy800
11/11 MN04902001Z-EN
www.eaton.com
•
Analog output QA01.
•
Output
…
QV of a different function block.
Function of the function block
The function block compares values present at the inputs I1 and I2.
The following contacts close depending on the comparison result:
•
I1 greater than I2, GT contact closes.
•
I1 equal to I2, EQ contact closes.
•
I1 less than I2, LT contact closes.
Memory
32 + per
4 Byte/Constant at function block input
Cycle time [
μ
s]
easy800 standard
easy800-SWD
24
8