*errors will be logged
** errors will not be logged
*** UI-error messages: higher priority overrules lower priority, with same priority message of first appearance is shown
July 2004
3 - 18
No.
Description
Over-
rules
Set condition
Reset condition
Remarks
Cause
Remedy
Prio-
rity***
81*
I/O module B is not
responding
10-26
Software operating
system
After ON/OFF/
CLEAR
switch in service mode, if
initialization has
indicated a successful
communication with the
I/O module.
A communication check
is carried out every 30
seconds.
A communi-
cation check is
carried out by
the software
every 30 sec.
After ON/OFF/
CLEAR wait 30
sec. and check,
if the error is
active.
1. Wiring incorrect or
connections defective
2. PCB B incorrectly
inserted in rack
3. PCB B defective
4. Middle fuse on switch
mode power pack
defective
1. Check wiring or replace
connections
2. Insert PCB B correctly in
rack
3. Replace PCB B
4. Replace middle fuse on
switch mode power pack
220
82*
I/O module C is not
responding
10-26
Software operating
system
After ON/OFF/
CLEAR
switch in Service mode,
if initialization has
indicated a successful
communication with the
I/O module.
A communi-
cation check is
carried out by
the software
every 30 sec.
After ON/OFF/
CLEAR wait 30
sec. and check,
if the error is
active.
1. Wiring incorrect or
connections defective
2. PCB C incorrectly
inserted in rack
3. PCB C defective
4. Middle and/or right
fuse on switch mode
power pack defective
1. Check wiring or replace
connections
2. Insert PCB C correctly in
rack
3. Replace PCB C
4. Replace middle and/or
right fuse on switch
mode power pack
220
Содержание Cafitesse 700
Страница 4: ......
Страница 6: ...July 2004 1 2 Cafitesse 700 Preface and safety instructions ...
Страница 12: ...July 2004 1 8 Cafitesse 700 Preface and safety instructions ...
Страница 39: ...July 2004 3 1 Table of contents Errors 3 ...
Страница 99: ...July 2004 4 36 Cafitesse 700 Programming ...
Страница 142: ...July 2004 5 8 Functions 5 3 General safety instructions ground connection safety circuit Cafitesse 700 Functions ...
Страница 174: ...July 2004 5A 32 Functions water system Cafitesse 700 Functions water system ...
Страница 175: ...July 2004 5B 1 Functions Brewing System B Brewing system Not applicable Cafitesse 700 Functions Brewing system ...
Страница 176: ...July 2004 5B 2 Functions Brewing System Cafitesse 700 Functions Brewing system ...
Страница 204: ...July 2004 5F 2 Functions cooling system Cafitesse 700 Functions cooling system ...
Страница 225: ...July 2004 5G 1 Functions housing G Housing G 1 Adjustments Not available here Cafitesse 700 Functions housing ...
Страница 232: ...July 2004 5G 8 Functions housing Cafitesse 700 Functions housing ...
Страница 252: ......
Страница 253: ......
Страница 254: ......
Страница 255: ......
Страница 257: ...July 2004 5K 30 Functions Power supply unit and control system Cafitesse 700 Functions power supply and control system ...
Страница 259: ...July 2004 5L 2 Functions external options Cafitesse 700 Functions external options ...
Страница 263: ...July 2004 5P 4 Functions payment systems Cafitesse 700 Functions payment systems ...