July 2004
4 - 17
MIXERS
Press the MIXERS soft key in the test menu. The
mixers test menu is opened. (Fig. 31)
This menu allows you to test the correct functioning of
each mixer.
Depending on the mixer test setting (see
section 'MIXER TEST' on page 24), the
trough must be in place or not. Check this
setting, if necessary. In addition, place a
container underneath each outlet to be tested.
During the test, the maximum current flowing through
each mixer is measured.
Press a START soft key to activate the corresponding
mixer. The currently measured current is displayed for
this mixer. Press the corresponding STOP soft key to
switch the mixer off again. The maximum current
measured for this mixer during the test is now indi-
cated.
TROUGH
Press the TROUGH soft key in the test menu. The
trough test menu is opened. (Fig. 32)
This menu allows you to test the correct functioning of
the product switches (ingredient switches) and the
corresponding hall sensors. Two sensors indicating the
current position are available for each switch.
Make sure that the trough is installed for this
test.
To test the product switches and sensors, press the
LEFT and RIGHT arrow soft keys. The switches are
moved accordingly to the left or to the right.
Depending on the position of the product switches, the
hall sensors must indicate '0' or '1' (0 = no switch
detected, 1 = switch detected).
COOLING TEMPERATURE
Press the COOLNG TMP soft key in the test menu.
The cooling temperature control test menu is opened.
(Fig. 33)
In this menu, you can test the correct functioning of
the Peltier cooling units. In addition, you get informa-
tion about the current cooling temperature as well as
the current flow through the Peltier units.
By default, the temperature is controlled
automatically.
Fig. 31
TEST: MIXERS
left
middle
right
START
START
START
STOP
STOP
STOP
I-max: 0.0
I-max: 0.0
I-max: 0.0
Fig. 33
TEST: COOLING TEMPERATURE CONTROL
Temperature control
: AUTOMATIC
Peltier units
: STAND-BY
Cooling temperature
: 3.2
°
C (69
Ω
)
Peltier current: L 0.9 A | R 0.9 A
AUTOMATIC
MANUAL
Fig. 32
0
LEFT
1
1
LEFT
RIGHT
0
RIGHT
TEST: TROUGH
Trough in place: YES
Cafitesse 700 - Programming
Содержание Cafitesse 700
Страница 4: ......
Страница 6: ...July 2004 1 2 Cafitesse 700 Preface and safety instructions ...
Страница 12: ...July 2004 1 8 Cafitesse 700 Preface and safety instructions ...
Страница 39: ...July 2004 3 1 Table of contents Errors 3 ...
Страница 99: ...July 2004 4 36 Cafitesse 700 Programming ...
Страница 142: ...July 2004 5 8 Functions 5 3 General safety instructions ground connection safety circuit Cafitesse 700 Functions ...
Страница 174: ...July 2004 5A 32 Functions water system Cafitesse 700 Functions water system ...
Страница 175: ...July 2004 5B 1 Functions Brewing System B Brewing system Not applicable Cafitesse 700 Functions Brewing system ...
Страница 176: ...July 2004 5B 2 Functions Brewing System Cafitesse 700 Functions Brewing system ...
Страница 204: ...July 2004 5F 2 Functions cooling system Cafitesse 700 Functions cooling system ...
Страница 225: ...July 2004 5G 1 Functions housing G Housing G 1 Adjustments Not available here Cafitesse 700 Functions housing ...
Страница 232: ...July 2004 5G 8 Functions housing Cafitesse 700 Functions housing ...
Страница 252: ......
Страница 253: ......
Страница 254: ......
Страница 255: ......
Страница 257: ...July 2004 5K 30 Functions Power supply unit and control system Cafitesse 700 Functions power supply and control system ...
Страница 259: ...July 2004 5L 2 Functions external options Cafitesse 700 Functions external options ...
Страница 263: ...July 2004 5P 4 Functions payment systems Cafitesse 700 Functions payment systems ...