July 2004
5C - 8
Functions - dosing system
C.3.2 Function: dosing system for product packs
2
3
1
•
The product pack is nonreturnable. The
pack consists of the cardboard box (1) with
the unit containing the concentrate bag (2)
including the dosing pump (3) inside.
(Fig. 1)
•
The dosing pump cannot be disassembled.
•
The concentrate bag including the dosing
pump is an airtight system.
This fact along with the product pack being
inserted in the cooling compartment en-
sures that:
-
no bacteria from the air can enter the
concentrate.
-
the durability and quality of the concen-
trate at 6
°
C (43
°
F) is guaranteed for a
period of up to 3 weeks for coffee.
•
The cooling compartment is equipped with
3 product packs. A dosing coil is situated
underneath the cooling compartment. The
dosing tube (4) including the dosing pump
reaches into the dosing coil. (Fig. 2)
•
The dosing coil and the dosing pump
constitute a system that is clocked from the
control system modules B and C on the
basis of electric current. For each pulse on
the dosing coil, the dosing pump provides
the following quantities:
-
coffee 0.105 cc
-
milk 0.09 cc
-
cocoa-containing beverage 0.09 cc
concentrate volume as follows:
The tappet, which consists of the tappet
ring (7), ring support (6) and inlet valve (8),
is pulled downwards. The bellows (9) filled
with concentrate is compressed and dis-
charges the concentrate via the outlet valve
onto the trough. Immediately after the
pulse, the bellows returns to its original
shape, and then the concentrate continues
to flow via the opened inlet valve (8) into
the bellows. (Fig. 2)
Fig. 1
Fig. 2
4
5
6
7
8
9
10
11
12
Legend Fig. 2:
4
dosing tube
5
floater
6
ring support
7
tappet ring
8
inlet valve
9
bellows
10
outlet connecting
piece
11
outlet valve
12
outlet nozzle
Cafitesse 700 - Functions - Dosing system
Содержание Cafitesse 700
Страница 4: ......
Страница 6: ...July 2004 1 2 Cafitesse 700 Preface and safety instructions ...
Страница 12: ...July 2004 1 8 Cafitesse 700 Preface and safety instructions ...
Страница 39: ...July 2004 3 1 Table of contents Errors 3 ...
Страница 99: ...July 2004 4 36 Cafitesse 700 Programming ...
Страница 142: ...July 2004 5 8 Functions 5 3 General safety instructions ground connection safety circuit Cafitesse 700 Functions ...
Страница 174: ...July 2004 5A 32 Functions water system Cafitesse 700 Functions water system ...
Страница 175: ...July 2004 5B 1 Functions Brewing System B Brewing system Not applicable Cafitesse 700 Functions Brewing system ...
Страница 176: ...July 2004 5B 2 Functions Brewing System Cafitesse 700 Functions Brewing system ...
Страница 204: ...July 2004 5F 2 Functions cooling system Cafitesse 700 Functions cooling system ...
Страница 225: ...July 2004 5G 1 Functions housing G Housing G 1 Adjustments Not available here Cafitesse 700 Functions housing ...
Страница 232: ...July 2004 5G 8 Functions housing Cafitesse 700 Functions housing ...
Страница 252: ......
Страница 253: ......
Страница 254: ......
Страница 255: ......
Страница 257: ...July 2004 5K 30 Functions Power supply unit and control system Cafitesse 700 Functions power supply and control system ...
Страница 259: ...July 2004 5L 2 Functions external options Cafitesse 700 Functions external options ...
Страница 263: ...July 2004 5P 4 Functions payment systems Cafitesse 700 Functions payment systems ...